5. Adjust the
Distance interval (mm)
setting, to set the distance between each label.
1.
Notes
The distance interval is measured from the start of one label to the start of
the next label.
2. Each label can also have its own "Distance between prints (mm)" value that
will override this setting, when printing is enabled. see
page 134
.
Distance Interval Measurement
End of procedure.
I/O FUNCTION ASSIGNMENT
Inputs
To assign functions to I/O inputs:
1. Select
Home > Setup > Production line setup > I/O
.
2. Select an input and assign a function:
Item
Details
Unassigned
No function.
Print Enable
Input used for continuous printing. While this input is held activate
and product movement is detected, the print group will print
continuously until product movement stops or the input is
deactivated.
Note
The label's Forward offset and Reverse offset
settings define the space between each label, see
Label Defaults on page 101
.
Message Increment
Increments the printing label.
Message Decrement
Decrements the printing label.
Message Reset
Resets the label selection back to the original start level.
Message 2^0
Input used for label selection, see
page 85
.
INSTALLATION
EPT053091 - Issue 5 - 07 May 2021
82
Summary of Contents for Gx-OEM
Page 1: ...Gx Series Product Manual Gx150i Gx350i Gx OEM ...
Page 63: ...3 Install the faceplate End of procedure INSTALLATION EPT053091 Issue 5 07 May 2021 58 ...
Page 65: ...3 Install the faceplate End of procedure INSTALLATION EPT053091 Issue 5 07 May 2021 60 ...
Page 122: ...The illustration below shows the Setup screen OPERATION 117 EPT053091 Issue 5 07 May 2021 ...