Name
Description
Mode
Select what action will occur when the printer receives data:
•
Print all
- Print all messages from the sender. After the
•
last message is printed, the printer will go to a "NO
DATA" state and wait for new data. If the product detect
sensor is triggered when there is no data, the printer will
stop and show an error.
•
Print last
- Only print the last message from the sender.
•
•
Print last and repeat
- Only print the last message from
•
the sender and continue to print the last message until
new messages are received.
Data type
Select the VDC data type:
•
JSON
•
•
Raw data
•
•
Customize.
•
Connection
Select the connection method:
•
TCP/IP
•
•
COM (RS485)
•
•
INPUT
•
•
Barcode scanner (connected via USB).
•
Response VDC Data
Turn this function On, to send a response to the sender when
VDC data is printed.
Response VDC Command Turn this function On, to send a response to the sender when
VDC data is received.
Controller port
Note
This setting is only valid if
Connection
is set to
TCP/IP
.
Select the printer's communication port.
Default: 2030
COM Port
Note
This setting is only valid if
Connection
is set to
COM
.
Select the printer's communication port.
Default: COM0
Data bits
Note
This setting is only valid if
Connection
is set to
COM
.
Select the number of data bits in each character:
•
4
•
•
5
•
•
6
•
•
7
•
•
8.
•
INSTALLATION
EPT077343 EN - Issue 1 - 11 November 2022
85
Summary of Contents for G Series
Page 1: ...G Series Product Manual G50i ...
Page 42: ...7 Fit the print head 7 INSTALLATION 42 EPT077343 EN Issue 1 11 November 2022 ...
Page 167: ...MAINTENANCE TROUBLESHOOTING EPT077343 EN Issue 1 11 November 2022 167 ...
Page 170: ...MAINTENANCE TROUBLESHOOTING 170 EPT077343 EN Issue 1 11 November 2022 ...