Name
Type
Description
9
PRINT_LED_DP
Output
Output to activate green beacon light.
Active low, open drain output.
47 K Ohm internal pull-up resistor to +24
V.
10
SP_INPUT
Input
Spare input.
Active low with 47 K Ohm internal pull-up
resistor to +24 V.
To use this input, connect Ground from
the input signal to Ground on the
printer's IO socket.
11
485A
RS485
Communication
RS485A, non-inverting driver output/
receiver input.
12
24V_FUSE
Output
24 V DC electrical power output.
Protected by a 3 A fuse.
Maximum current output: 1.5 A.
This output is combined/shared with #5.
13
GROUND
-
14
SP_SIG_DP
Output
Spare output.
Active low, open drain output.
47 K Ohm internal pull-up resistor to +24
V.
15
ALARM_LED_DP
Output
Output to activate green beacon light.
Active low, open drain output.
47 K Ohm internal pull-up resistor to +24
V.
SYSTEM DESCRIPTION
EPT077343 EN - Issue 1 - 11 November 2022
27
Summary of Contents for G Series
Page 1: ...G Series Product Manual G50i ...
Page 42: ...7 Fit the print head 7 INSTALLATION 42 EPT077343 EN Issue 1 11 November 2022 ...
Page 167: ...MAINTENANCE TROUBLESHOOTING EPT077343 EN Issue 1 11 November 2022 167 ...
Page 170: ...MAINTENANCE TROUBLESHOOTING 170 EPT077343 EN Issue 1 11 November 2022 ...