EN
HC302D, HC502D
Troubleshooting
23
9
Troubleshooting
Water in or under the refrigerator
Display error messages
Fault
Possible cause
Remedy
Water is leaking into the
inside of the
refrigerator.
The condensate drain duct is
clogged.
Clean the drain.
Medicines are preventing the water
from flowing to the collector.
Make sure that medicines
do not touch the rear
wall.
Water is leaking onto
the floor.
There is too much water in the water
container.
Clean the water
container.
Error code
Explanation
E0
Display/Control communication failed
E1
NTC1 short circuited or open connection
E2
NTC2 short circuited or open connection
E3
Battery not connected or not OK
E4
Fan not working
E5
Door open for more than 60 seconds
E6
Temperature outside range (lower 2 °C or higher 8 °C)
E7
Mains not connected
E8
Too much difference between NTC1 and NTC2 values
DometicHC302D-HC502D_IOM_4445101933_EMEA(en-de-fr-nl)_202x-xx-xx.book Seite 23 Mittwoch, 24. Februar 2021 2:57 14