background image

6

2. Once the lower front strip is slipped under the

hinge, the part is possible to swing into place as

shown in FIG. 6.

3. Secure the refrigerator and the lower front strip

with two screws:
One screw through the hinge, and on the opposite

side one screw through the lower front strip. (FIG. 6).

STEP 2: Two screws installed in the top frame.

The top decoration panel must be removed from the re-

frigerator before the screws can be installed.

Open the door and gently push the tabs out of the hole

in the hinge with a flat blade screwdriver, (both sides).

See FIG. 7.

Carefully tilt the top decoration panel and lift up to re-

move from top frame. Be careful not to damage the cir-

cuit board and wires.

Any space between the counter, storage area or ceiling

and  top  of  the  refrigerator  greater  than  1-1/2  inches

should be blocked. The heat produced at the rear of the

refrigerator will become trapped in this space, making

the top of the refrigerator hot and reduce the efficiency

of the refrigerator.

Drain water hose

A hole must be drilled through flooring see FIG. 8.

The installer MUST make sure that the hose does not

kink when run through the floor. Seal around the hose

that goes through the drilled hole. If a longer hose than

supplied is required to get the water to drain outside of

the vehicle, the installer will have to supply the extra

length of hose.

TESTING LP GAS SAFETY SHUTOFF

The gas safety shutoff must be tested after the re-

frigerator is connected to the LP gas supply.

To test the gas safety shutoff, proceed as follows:

1. Start the refrigerator and switch to GAS mode. (See

start up instructions).

2. Check that the gas flame is lit and the GAS mode

indicator lamp (C) is on.

3. Close the manual gas shutoff valve at the back of

the refrigerator. (See FIG. 1).

4. Wait for one minute. The CHECK indicator lamp (E)

should be on and the GAS mode indicator lamp (C)

should be off.

5. Remove protection cover (see FIG. 1) and open

the manual gas shutoff valve. Do not change any

button positions on the control panel. Apply a non-

corrosive commercial bubble solution to the burner

jet orifice.

6. No bubbles should appear at the opening of the

burner jet orifice. The presence of bubbles indi-

cates a defective gas safety shutoff, and service is

required.

7. If no bubbles were present at the burner jet orifice,

it should be rinsed with fresh water. Be careful not

to damage the burner jet orifice. Replace cover and

press the main power ON/OFF button (1) OFF and

back ON. Normal operation of the burner should

return. Allow the burner to operate for a minimum

of 5 minutes.

3

FIG. 6

FIG. 7

1

2

Install the two screws in the top frame, the holes are

accessible from underneath.

Seal the opening for the screws with aluminum tape.

Replace the top decoration panel. Be careful not to pinch

the wires behind the panel.

Make sure the tabs snap back into the holes in the hinge

plate.

STEP 3: Two screws installed in the rear base.

See FIG. 8

Failure to follow the sequence in securing the refrigerator

in the enclosure can cause leakage between the frame

and cabinet.

FIG. 8

Hole for drain water hose

All manuals and user guides at all-guides.com

all-guides.com

Summary of Contents for RM3662

Page 1: ...o this manual For assistance or additional information consult a qualified installer service agency or the gas supplier AVIS Cet appareil doit tre r par seulement par un r parateur autoris Modificatio...

Page 2: ...All manuals and user guides at all guides com...

Page 3: ...Control Switch H Low Ambient Switch LEGEND 3 WAY AMES Model 1 Main Power Button ON OFF 2 DC Mode Selector Button 3 AUTO GAS Mode Selector Button 4 Temperature Selector Button A DC Mode Indicator Lamp...

Page 4: ...modification An opening toward the outside at floor level in the refrigerator compartment must be provided for ventilation of heavier than air fuel gases The lower vent of the recommended kits is prov...

Page 5: ...he wood strip with screws See FIG 10 The refrigerator must be installed in a substantial enclo sure and must be level When installing the refrigerator in the enclosure all areas within the recess in w...

Page 6: ...s supply To test the gas safety shutoff proceed as follows 1 Start the refrigerator and switch to GAS mode See start up instructions 2 Check that the gas flame is lit and the GAS mode indicator lamp C...

Page 7: ...tilation height see table VENTILATION HEIGHTS See Figures 9 and 10 METHODS OF INSTALLATION The method of installation is shown in FIG 9 It is essential that all maximum or minimum dimensions are stric...

Page 8: ...g movement of the vehicle will pass to either side of level keeping the liquid ammonia from accumulating in the evaporator tubing OPERATION Before starting the refrigerator check that all the manual g...

Page 9: ...light START UP INSTRUCTIONS A A continuous 12 volt DC supply must be available for the electronic control to function B Press the main power ON OFF button 1 to the DOWN position C Press the TEMPERATUR...

Page 10: ...mp is on it will function properly but the CHECK indicator lamp will not go off until the main power ON OFF button is pressed to the OFF then ON position DC MODE 3 way models only When operating in th...

Page 11: ...if the thermostat is set at its highest position It is a good idea to do this a few hours before the antici pated need for ice but be sure to move back to normal setting usually about mid setting whe...

Page 12: ...gas systems and refrigerators 1 REFRIGERATOR REMOVAL Before working on the refrigerator make sure the AC voltage and DC voltage leads are disconnected Shut off the gas supply at the LP tank Disconnect...

Page 13: ...nance Service item 2 Periodic Maintenance Paragraph E item 1 14 WARNING DO NOT use a flame to check for gas leaks C Check the AMES control system by connecting dis connecting 120 volt AC power start s...

Page 14: ...s of the door frame 3 C Push the panel downward so that the lower hori zontal edge of the panel 4 is fitted into the bottom grove 5 D Put the decoration strip across the door so that the gap is covere...

Page 15: ...T NO RM 3662 4A Roof Base 3103633 XXX RM 3663 Roof Cover 3103634 XXX RM 3862 RM 3863 Lower Side Vent 3109350 XXX Fill in XXX with color code numbers For color codes contact your supplier For further i...

Page 16: ...the wire shelf to the left The right hand side of the shelf will come loose Slide the shelf into the holes on the right hand side Lower the right hand side of the wire shelf and let the left hand side...

Page 17: ...17 RM 3662 RM 3862 RM 3663 RM 3863 All manuals and user guides at all guides com...

Page 18: ...18 All manuals and user guides at all guides com...

Page 19: ...19 All manuals and user guides at all guides com...

Page 20: ...20 MO FO 0233 All manuals and user guides at all guides com...

Reviews: