background image

13

B. Check all connections in the LP gas system (at the

back of the refrigerator) for gas leaks. The LP gas

supply  must  be  turned  on.  Apply  a  non-corrosive

bubble solution to all LP gas connections.
The  appearance  of  bubbles  indicates  a  leak  and

should be repaired 

immediately

 by a QUALIFIED

SERVICEMAN WHO IS FAMILIAR WITH GAS SYS-

TEM AND REFRIGERATORS.

DO NOT use a wire or pin when cleaning the burner

jet as damage can occur to the precision opening.

This can cause damage to the refrigerator or create

a fire hazard.

FIG. 13

Clear blue color

of flame

! WARNING

10. Reinstall burner, being careful that the end of the

burner fits into the slot on the burner bracket. Check

to make sure slots are centered under the flue tube

and the thermocouple is positioned properly (tip of

thermocouple extends over two slots of burner).

11. Be sure to reconnect the wire to high voltage elec-

trode. Check the electrode for proper location and

gap. (See FIG. 14).

12. Turn on manual gas shutoff valve and check all fit-

tings for leaks with soapy water.

13. Connect 120 volt power cord to the outlet and re-

connect or turn on the 12 volt DC power.

14. Check LP gas safety shutoff. See page 6.

TROUBLESHOOTING
The Refrigerator Does Not Cool Properly

A. Burner jet clogged.

Clean. (See Section Maintenance & Service, item 2.

Periodic maintenance, Paragraph E item 1-14.

B. Check level of refrigerator.
C. Venting problem.

Restriction in air flow across cooling unit.

D. Heavy frost buildup on evaporator fins.

Defrost.

E. Flue baffle not inserted properly in flue tube.
F. Improperly set thermostat.

See section Operating Instructions, part Start Up

Instructions.

G. Burner dirty.

Clean. (See section Maintenance & Service, item 2.

Periodic Maintenance, Paragraph E item 1-14).

! WARNING

DO NOT use a flame to check for gas leaks.

C. Check the AMES control system by connecting/dis-

connecting 120 volt AC power, start/stop the engine,

etc. Compare the operation with the operation de-

scribed in section Operating Instructions.

D. The LP gas pressure should be checked and the main

regulator readjusted if pressure is incorrect. The cor-

rect operating pressure is 11 inches of water column.

The correct place to take the LP gas pressure is at

the test port just ahead of the burner jet. (See FIG. 12).

E. Inspect the flue baffle. It should be reasonably clean

and free of soot. Heavy soot formation indicates im-

proper functioning of the burner. The flue and burner

both require cleaning in the following manner:

1. Unplug the refrigerator power cord from the 120 volt

AC outlet. (See FIG. 3).

2. Disconnect or shut off the 12 volt DC power to the

refrigerator.

3. Turn manual shutoff valve to OFF. (See FIG. 1 & 12).
4. Remove cover from the burner housing. (See FIG. 1).
5. Disconnect the wire from the high voltage electrode.
6. Remove the burner mounting screw and remove the

burner assembly. (See FIG. 12).

7. Remove the wire and flue baffle from the top of flue

tube. Clean the flue from the top using a flue brush.

Blowing compressed air into the flue 

will not

 properly

clean soot and scale out of the flue tube. Replace

the flue baffle.

8. Clean burner tube with a brush. Blow out burner with

compressed air.

9. Before removing burner jet, clean burner area of soot

and scale that fell out of flue tube. Remove the burner

jet. Soak the jet in wood alcohol and blow it out with

compressed air. Reinstall and tighten burner jet.

NOTE:

 The color of the flame shall be clear blue over

the slots of the burner. (See FIG. 13).

FIG. 14

Electrode

Burner tube

1/8” to 3/16”

(3-5 mm)

All manuals and user guides at all-guides.com

Summary of Contents for RM3662

Page 1: ...o this manual For assistance or additional information consult a qualified installer service agency or the gas supplier AVIS Cet appareil doit tre r par seulement par un r parateur autoris Modificatio...

Page 2: ...All manuals and user guides at all guides com...

Page 3: ...Control Switch H Low Ambient Switch LEGEND 3 WAY AMES Model 1 Main Power Button ON OFF 2 DC Mode Selector Button 3 AUTO GAS Mode Selector Button 4 Temperature Selector Button A DC Mode Indicator Lamp...

Page 4: ...modification An opening toward the outside at floor level in the refrigerator compartment must be provided for ventilation of heavier than air fuel gases The lower vent of the recommended kits is prov...

Page 5: ...he wood strip with screws See FIG 10 The refrigerator must be installed in a substantial enclo sure and must be level When installing the refrigerator in the enclosure all areas within the recess in w...

Page 6: ...s supply To test the gas safety shutoff proceed as follows 1 Start the refrigerator and switch to GAS mode See start up instructions 2 Check that the gas flame is lit and the GAS mode indicator lamp C...

Page 7: ...tilation height see table VENTILATION HEIGHTS See Figures 9 and 10 METHODS OF INSTALLATION The method of installation is shown in FIG 9 It is essential that all maximum or minimum dimensions are stric...

Page 8: ...g movement of the vehicle will pass to either side of level keeping the liquid ammonia from accumulating in the evaporator tubing OPERATION Before starting the refrigerator check that all the manual g...

Page 9: ...light START UP INSTRUCTIONS A A continuous 12 volt DC supply must be available for the electronic control to function B Press the main power ON OFF button 1 to the DOWN position C Press the TEMPERATUR...

Page 10: ...mp is on it will function properly but the CHECK indicator lamp will not go off until the main power ON OFF button is pressed to the OFF then ON position DC MODE 3 way models only When operating in th...

Page 11: ...if the thermostat is set at its highest position It is a good idea to do this a few hours before the antici pated need for ice but be sure to move back to normal setting usually about mid setting whe...

Page 12: ...gas systems and refrigerators 1 REFRIGERATOR REMOVAL Before working on the refrigerator make sure the AC voltage and DC voltage leads are disconnected Shut off the gas supply at the LP tank Disconnect...

Page 13: ...nance Service item 2 Periodic Maintenance Paragraph E item 1 14 WARNING DO NOT use a flame to check for gas leaks C Check the AMES control system by connecting dis connecting 120 volt AC power start s...

Page 14: ...s of the door frame 3 C Push the panel downward so that the lower hori zontal edge of the panel 4 is fitted into the bottom grove 5 D Put the decoration strip across the door so that the gap is covere...

Page 15: ...T NO RM 3662 4A Roof Base 3103633 XXX RM 3663 Roof Cover 3103634 XXX RM 3862 RM 3863 Lower Side Vent 3109350 XXX Fill in XXX with color code numbers For color codes contact your supplier For further i...

Page 16: ...the wire shelf to the left The right hand side of the shelf will come loose Slide the shelf into the holes on the right hand side Lower the right hand side of the wire shelf and let the left hand side...

Page 17: ...17 RM 3662 RM 3862 RM 3663 RM 3863 All manuals and user guides at all guides com...

Page 18: ...18 All manuals and user guides at all guides com...

Page 19: ...19 All manuals and user guides at all guides com...

Page 20: ...20 MO FO 0233 All manuals and user guides at all guides com...

Reviews: