Dometic RM1350 Troubleshooting Guide for Poor Cooling

For use when the temperature indicator is consistently greater than 39 degrees  

Assumed to be running on 110V shore power, 

Temp Setting on ‘5’

Were doors 

open for more 

than 30 

seconds?

Allow several hours to 

reach normal temp

YES

Is frig full & 

tightly packed

With food?

Leave room for air 

circulation and add small 

fan to shelf

YES

Are

large items

blocking air

circulation

NO

YES

Freezer

cooling 

properly?

YES

Freezer

cools ok in

LP mode?

Run for 1-2 days
On LP instead of 

Electric

  Electric Boiler 

needs service

3

.

YES

Is Frig out of 

level more

Than slightly?

Level trailer, espec

Front-to-rear.

YES

External temp

> 95 degrees?

Improve airflow

On back of frig

1

Endcap 

missing from

Drain hose?

Replace endcap

Left

door flap

not closing

tightly?

Install improved 

flap mounting 

brackets

2

YES

Dollar bill 

Pulls thru seals

easily

Adjust doors or fix/

replace seals

YES

YES

NO

NO

Thermistor

Near fins?

If adjustable, move 

away from fins

YES

NO

YES

NO

NO

Ammonia 

smell?

Probably need 

new cooling unit

Get service to test

Cooling unit per

Dometic specs

YES

1. Add ventilator fan kit 3108705.744 (or equivalent) and check that baffle is directing air across the condenser fins before exiting top vent.

2. Flap mounting brackets: new part #s 3851102024 and 3851103022

START

HERE

Freezer should cool to 

around 0 degrees F.  Ice 

cream should be hard.

3. User manual has instructions on replacing electric heating unit.  With heater leads removed, element should show 40-70 ohms

NO

Fan 

On backside

Of frig

stopped?

NO

Repair/replace fan

YES

NO

NO

NO

Problem

Happens only

every few

days?

NO

NO

Restart auto-defrost cycle.  

At 4PM, cut all AC and DC 

power, then restart frig.

YES

Dometic RM1350 Troubleshooting Flowchart