8 Using the device
8.1 Device elements
8.2 LED indications
8.3 Switching between battery banks
In some applications, two battery banks with different nominal voltages need to be charged from the same solar
panels. An external switch or relay can be used to select which battery bank is charged by the controller.
The controller automatically determines nominal system voltage at startup. If there is a large jump in battery voltage
(i.e. switching from one battery bank to another with a different nominal voltage), then the controller will detect the
new nominal system voltage and reset.
NOTE
When the solar panel is exposed to light, it supplies a DC voltage to the solar charge
controller.
Description
1
Controller LED (green)
2
Solar LED (red)
3
Battery LED (red)
4
Temperature sensor
5
Positive solar panel connection
6
Negative solar panel connection
7
Battery connection
LED
Status
Indication
On
Controller connected to battery, night or no solar panel volt-
age detected.
Flashes
Controller connected to battery, day detected.
Off
Battery connected with reverse polarity or not connected.
On
Charging failure (solar panel overvoltage or overcurrent).
Off
Normal charging status.
On
Very low battery voltage or battery overvoltage.
Off
Battery voltage in normal range.
All
Green - red - green