Page 1: ...RTER User Manual GP ISW 200 400 2021 Go Power Worldwide Technical Support and Product Information gpelectric com Go Power Dometic 201 710 Redbrick Street Victoria BC V8T 5J3 Tel 1 866 247 6527 82654_M...

Page 2: ...e protection features Input over under voltage protection Internal over temperature protection Input reverse polarity protection fuse Output overload protection Output short circuit protection Product...

Page 3: ...NECTIONS 20 3 3 5 WIRING THE INVERTER TO THE BATTERIES 21 3 3 6 DC GROUNDING 22 3 4 AC WIRING 22 3 4 1 AC OUTPUT INTERFACE 23 3 4 2 GP ISW 200 400AC OUTPUT INTERFACE 23 4 OPERATION 25 4 1 FINAL INSPEC...

Page 4: ...national electrical codes These instructions are for use by qualified personnel who meet all local and governmental code requirements for licensing and training for the installation of electrical powe...

Page 5: ...ny way See the Warranty section for instructions on returning the equipment WARNING Hazard to Human Life This type of notation indicates that the hazard could be harmful to human life WARNING Shock Ha...

Page 6: ...ats etc Use standard safety practices when working with electrical equipment Remove all jewelry use insulated tools wear cotton clothing etc Never work alone when installing or servicing this equipmen...

Page 7: ...Hazard Do not keep combustible or flammable materials in the same room with the equipment Some products contain relays with moving parts and are not ignition protected Ensure AC DC and ground cable s...

Page 8: ...a spark IMPORTANT Use the battery types recommended by Go Power Follow the battery manufacturer s recommendations for installation and maintenance Insulate batteries as appropriate against freezing t...

Page 9: ...inspect the equipment prior to energizing Verify that no tools or equipment have been inadvertently left behind Ensure clearance requirements are strictly enforced Keep all vents clear of obstruction...

Page 10: ...rect reliable or current The specifications in this manual are for reference purposes only and are subject to change without notice For additional information please see www gpelectric com DISCLAIMER...

Page 11: ...parts shown in the list below are included in the kit If any parts are missing please contact Go Power customer service team at customersupport gpelectric com or 1 866 247 6527 2 3 1 PARTS CHECKLIST I...

Page 12: ...68 GP ISW400 187 35 7 116 150 8 0 68 GP ISW700 330 80 132 200 7 0 83 GP ISW1000 372 69 196 200 7 0 83 GP ISW1500 421 92 196 248 7 0 83 GP ISW2000 443 103 196 248 7 0 83 GP ISW3000 442 103 196 255 7 0...

Page 13: ...oad Protection Input Over Voltage Protection 16 0VDC 3 32 0VDC 3 Input Under Voltage Protection 10 0VDC 3 20 0VDC 3 BAT Low Shutdown 10 0VDC 3 20 0VDC 3 BAT Low Alarm 10 5VDC 3 21 0VDC 3 BAT Low Resta...

Page 14: ...ble 4 GP400 for output 100 110 115 120 VAC specification Note Normal load Condition Vin 12 5V 25V 50V Vo 100 110 115 120 VAC 80 load PF 1 0 Voltage performance Please refer to Figure 2 Temperature per...

Page 15: ...ndition Figure 1 GP ISW 200 400 front panel view 3 INSTALLATION 3 1 TYPICAL SYSTEM OVERVIEW The following diagrams show how the GP ISW Inverter and GP ISW R are typically installed in a mobile RV appl...

Page 16: ...e liquids gasoline cloths that may be ignited by heat sparks or flames Never place the Inverter directly above the battery bank gases from the batteries will corrode and damage the Inverter never allo...

Page 17: ...ZONTAL WALL MOUNT BASE DOWN HORIZONTAL WALL MOUNT BASE DOWN HORIZONTAL MOUNT BASE DOWN HORIZONTAL MOUNT BASE UP VERTICAL MOUNT DO NOT MOUNT THE GP ISW IN THIS CONFIGURATION GP ISW model may not be exa...

Page 18: ...eform and reduces the wear of the Inverters filter capacitors To ensure optimum Inverter performance the number of connections between the battery bank and the GP ISW unit should be minimized except f...

Page 19: ...your wire runs as short as possible helps to prevent low voltage shutdowns and nuisance tripping of the DC breaker because of increased current draw The table below shows the recommended DC cable siz...

Page 20: ...vercurrent protection then a separate disconnect switch will need to be installed 3 3 3 PREPARING THE DC CABLES Go Power supplies 2 ring lugs with the GP ISW which can be used for the Inverter end of...

Page 21: ...voltage of your inverter The interconnecting wires between the individual batteries must be sized and rated exactly the same as those used between the battery bank and Inverter To ensure the best perf...

Page 22: ...C panel is normally used to connect the batteries and distribute DC power to the Inverter and to the other DC loads A common earth ground should be used to bond the Inverter negative bus bar and the n...

Page 23: ...ts A GFCI is a device that de energizes a circuit when a current exceeds a specified value that is less than that required to open the circuit breaker GFCIs are intended to protect people from electri...

Page 24: ...red light quickly twice every 1 6 seconds O P short circuit LED lights red following two short beeps Inverter shuts down after two seconds and restart 3 times O P over load LED lights red following t...

Page 25: ...short beeps Over voltage InputDCvoltageover spec LED fast blink Under voltage Input DC voltage under spec LED slow blink with one long beeps two short beeps Table 8 GP400 LED status 3 1 3 AC Output 4...

Page 26: ...and verify it comes on and shines normally 5 Press the ON OFF button The inverter and LED lights will turn off 4 3 CONNECTING THE AC LOADS Calculate the total power consumption of the output load Make...

Page 27: ...cuit and over load Red Blink Under Voltage Protection Input DC voltage under spec 12 5V DC12V system 25V DC24V system Red Fast Blink Over Voltage Protection Input DC voltage over spec 14 5V DC12V 29V...

Page 28: ...VOLTAGE SELECTION S1 S2 Output Voltage S1 S2 100V OFF OFF 110V OFF ON 115V ON OFF 120V ON ON 4 5 2 OUTPUT FREQUENCY SELECTION S3 Frequency S3 50Hz OFF 60Hz ON 4 6 POWER SAVING SELECTION S4 Saving Func...

Page 29: ...tage DC Shutdown Restart Shutdown Restart 12V 16V 0 3V 14 5V 0 3V 10 5V 0 3V 10V 0 3V 12 5V 0 3V 24V 33V 0 5V 29V 0 5V 21V 0 5V 20V 0 5V 25V 0 5V GP ISW200 Over Temperature Protection Shutdown Restart...

Page 30: ...on of our website to troubleshoot the problem If trouble persists 1 Call your Go Power Technical Support team 1 866 247 6527 or 2 Return defective product to place of purchase Unless approved by Go Po...

Page 31: ...ntre Knowing for sure if your appliances are being recycled properly is tricky If you re in doubt just ask Recyclers that are certified should gladly show you their certification If the re cycler is c...

Page 32: ...2021 Go Power Worldwide Technical Support and Product Information gpelectric com Go Power Dometic 201 710 Redbrick Street Victoria BC V8T 5J3 Tel 1 866 247 6527 82654_MAN_ISW200 400_RevA...