7
1
Notes on using the manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2
General safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3
Intended use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 - 8
4 Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
5 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 - 9
6 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 - 10
7 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
8
Warranty and Product Liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 - 12
1
Notes on using the manual
Note
Supplementary information for operating the device .
fig. 2 A, page 2 :
This refers to an element in an illustration . In this example, item A in
figure 2 on page 2 .
2
Caution!
Safety Instruction:
Failure to observe this instruction can cause material damage and
impair the function of the device .
EN
Table of contents
Dometic Tank Monitor System
Notes on using the manual
2
General safety instructions
The manufacturer will not be held liable for claims for damage resulting from the following:
• Faulty assembly or connection
• Damage to the unit from mechanical influences, misuse or abuse
• Float switches fouled with tissue paper
• Alterations to the unit without express written permission from the manufacturer
• Use for purposes other than those described in this manual
3
Intended use
3.1
OPTION 1: DTM04 tank monitor system
DTM04 Tank Monitor System provides electronic monitoring of the liquid level inside a holding tank .
Three float switches inside the tank activate a set of four lights on an indicator panel . The lights indicate
Empty, Low, Mid and Full levels . The Full level indicates when the liquid level is within 51 mm (2 in .) of
the top of the holding tank . The other float switches are connected to adjustable probe stems which
can be positioned according to the tank height and the desired indicator panel readings .
3.2
OPTION 2: DTM04 tank monitor system with “full tank” shut-down relay
When the optional “Full Tank” Shut-down Relay (available separately) is connected to the DTM04 panel,
and the holding tank reaches the Full level, the relay shuts off power to the electric toilet . This prevents
use of the toilet and the possibility of overfilling the holding tank . See Components for “Full Tank” Shut-
down Relay item numbers . The relay handles a maximum electrical current of 30 amps .
Summary of Contents for DTM04
Page 2: ...2 Dometic Tank Monitor System 1 2 4 3 5 6 7 8 9 10 A B C D E F G H 1 2...
Page 3: ...3 1 4 1 2 5 7 6 2 3 A B 3 4 Dometic Tank Monitor System...
Page 4: ...4 Dometic Tank Monitor System 1 2 3 4 5...
Page 5: ...5 Dometic Tank Monitor System 6 A C H G F B D E...
Page 6: ...6 Dometic Tank Monitor System...
Page 69: ...69...
Page 70: ...70...