![Dometic DE15F Installation And Operating Manual Download Page 41](http://html1.mh-extra.com/html/dometic/de15f/de15f_installation-and-operating-manual_2519301041.webp)
EN
D E15F, DE24F, EA15F, EA24B, EA24D, EA24F
Legal
41
Follow EPA use conditions.
15
Legal
This device complies with Part 15 of the FCC Rules. Operation is subject to the fol-
lowing two conditions:
•
This device may not cause harmful interference.
•
This device must accept any interference received, including interference that
may cause undesired operation.
Changes or modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate the equipment.
EA24B
EA24D
EA24F
Input voltage
110 – 120 V
60 Hz
Total volume
150 l
Rated input power
110 W
Ambient temperature
10 °C (50 °F) to 38 °C (100 °F)
Storage temperature range
0 °C (32 °F) to 22 °C (72 °F)
Noise emission
45 dB
Propellant
Cyclopentane
Refrigerant
R600a
Dimensions
Weight
42 kg
49 kg
36.5 kg
Certifications
DometicD15F-24F_E15F-24B-24D-24F_IOM_4445103817_AMER3_202x-xx-xx.book Page 41 Wednesday, December 7, 2022 9:56 AM