8.2
P.01: Low voltage shut-down
The battery monitor protects the battery against discharging excessively.
A
If only the power supply voltage specified here is available to the parking cooler,
the system is switched off.
➤
Switch to configuration mode (chapter “Entering and exiting configuration
mode” on page 12).
✓
The display shows “P.01” and the symbol
flashes.
➤
Press the
button to change the setting.
✓
The current setting is displayed.
➤
Use the
or
button to select the voltage level for low voltage shut-
down.
The low voltage shut-down setting can be adjusted in 0.1 V increments from
20.0 V to 23.5 V.
I
➤
Press the
button to save the setting.
✓
The set value is saved and is then applied when the system is restarted.
✓
You are then returned to the menu and can select another menu item by
pressing the
or
button.
NOTICE!
If the unit is switched off by the battery monitor, it means the battery charge
level is low. Avoid repeated starting or using electrical equipment. Make sure
that the battery is recharged. As soon as the required voltage is available again,
the system can be operated again.
NOTE
The level for the low voltage shut-down should not be set any lower than the
minimum battery voltage required to be able to start the engine under any
conditions.
As a rule that should be no less than 22 V.
RTX1000-2000-SPX1200T-Scania-NG--I-16s.book Seite 13 Montag, 7. Oktober 2019 7:21 19