background image

Breathe

 

Easy™

_BreatheEasy_A5.book  Seite 1  Dienstag, 24. Januar 2012  3:31 15

For Sales Information Please Contact 

RoadTrucker Inc 

(www.RoadTrucker.com) 

8312 Sidbury Rd. 

Wilmington, NC 28411 

(800) 507-0482 / (910) 686-4281

Summary of Contents for breath easy

Page 1: ...the Easy _BreatheEasy_A5 book Seite 1 Dienstag 24 Januar 2012 3 31 15 For Sales Information Please Contact RoadTrucker Inc www RoadTrucker com 8312 Sidbury Rd Wilmington NC 28411 800 507 0482 910 686...

Page 2: ...isk of exposure to UV radiation take UV radiation protective measures for personnel during servicing Ultraviolet lamp may cause injury Ultraviolet lamps are made of glass and are fragile Safety eyewea...

Page 3: ...4 8 Using the Breathe Easy 25 9 Replacing the ultraviolet lamp and the nano mesh divider 25 10 Cleaning and caring for Breathe Easy 27 11 Troubleshooting 28 12 Guarantee 29 13 Disposal 29 14 Technical...

Page 4: ...l damage and impair the function of the product I NOTE Supplementary information for operating the product Action This symbol indicates that action is required on your part The required action is desc...

Page 5: ...damaged This device may only be repaired by qualified personnel Inadequate repairs can lead to serious hazards Should your device need to be repaired please contact customer services Persons whose phy...

Page 6: ...Risk of exposure to excessive ultraviolet UV radiation Do not operate without complete lamp enclosure in place A NOTICE Only use the device indoors never outside Never expose the device to moisture M...

Page 7: ...uality by constantly circulating the air through the device I NOTE Note that the device does not fix the the source of ongoing odor problems For example a leak that caused mold must be repaired and th...

Page 8: ...e materials are stored or flammable gases may accumulate Do not install the device near the inlet or outlet of an air conditioning system Keep the power cable away from hot surfaces Install the device...

Page 9: ...p is on you can see a blue glow through the vents I The fan operates at lower speed The ultraviolet lamp is on you can see a blue glow through the vents 0 The fan and the ultraviolet lamp are switched...

Page 10: ...t you know when the ultraviolet lamp needs to be replaced Lift the nano mesh divider fig 1 2 page 3 out of the slots Insert the new nano mesh divider lengthways into the slots It does not matter which...

Page 11: ...nterior with canned air to blow out any dust Clean the fan fig 1 1 page 3 with a soft brush when you replace the ultraviolet lamp or if you notice a reduction in the air flow Clean the removable nano...

Page 12: ...d the nano mesh divider on page 25 Check whether the lamp socket fig 1 5 page 3 is defective Output seems ineffective Make sure the device is correctly installed In an enclosed room Not near the inlet...

Page 13: ...e A reason for the claim or description of the fault Guarantee does not cover the ultraviolet lamp 13 Disposal Place the packaging material in the appropriate recycling waste bins wherever possible M...

Page 14: ...asy SKU 9108680632 Voltage 12 Vg Current 666 mA Consumption 8 W Maximum room size 46 m 500 sq ft Dimensions W x D x H 158 x 114 x 48 mm 6 2 x 4 5 x 1 9 Weight Approx 340 g 12 oz Testing certification...

Page 15: ...il info dometic ru U Dometic Scandinavia AB Gustaf Melins gata 7 S 42131 V stra Fr lunda G teborg 46 31 7341100 46 31 7341101 Mail info waeco se 4 Dometic UK Ltd Dometic House The Brewery Blandford St...

Reviews: