Using the inverter
45
Switching to energy-saving mode
You can set the energy-saving mode using the S4, S5 and S6 dip switches.
In this way, the battery you connect to the inverter is not discharged as quick-
ly.
The inverter operates in energy-saving mode as long as the required power
is below the set level. If the required power exceeds the set level, the inverter
works in normal mode.
The values to be set on your inverter can be found in the following table:
Defining settings
Using the S8 dip switch you can define whether the default settings or the
settings of dip switches S1 – S7 are used.
Default settings
Energy-saving
mode
Dip switch
S4
S5
S6
Off
Off
Off
Off
–
On
Off
Off
70 – 110 W
On
On
Off
180 – 240 W
On
On
On
Dip switch
Parameter
S8
Default settings
On
Use dip switch S1 – S7
Off
Mains voltage
Net frequency
Energy-saving mode
230 V
50 Hz
Off