Installation of an ENiQ Module Reader/Module Reader Terminal
59
Installation of an ENiQ Module Reader/Module Reader Terminal
The ENiQ Module Reader or Module Reader Terminal devices consist of an
Access Manager Compact or Access Manager Terminal Compact (control
unit) and an external reader. Proceed in the following sequence for
installation:
Install the mounting frame of the Access Manager (control unit) on the wall
with and without surface-mounting frame.
Install the external reader and connect Access Manager Compact or Access
Manager Terminal Compact (control unit).
Connect the Access Manager Compact or Access Manager Terminal
Compact (control unit) to the network.
Connect the external reader and Access Manager Compact or Access
Manager Terminal Compact (control unit) to the power supply.
Completing the installation of the ENiQ Module Reader or Module Reader
Terminal
Installation of the mounting frame on the wall with and without
surface-mounting frame
WARNING
Risk of injury through electric current when drilling into a live
cable.
Make sure you do not drill into any live cables when drilling
holes.
Before any drilling work, use a cable detector to find any
cables in the wall.
CAUTION
Risk of eye injuries through drilling dust.
Wear safety goggles.
Use equipment to extract the drilling dust.
CAUTION
Risk of finger or hand injuries caused by slipping during
drilling or screwing work.
Wear suitable safety gloves.
Observe and follow the notices provided in the drilling
machine documentation when drilling.