Dolphin 399050 Technical Manual Download Page 6

NOT-PREMIUM900W-01

4

The mains and battery connections must be 

disconnected before any work is carried out in 

order to avoid transfer of energy 

4

Fuses must be replaced by fuses that have the 

same characteristics and performance levels.

SAFETY PRECAUTIONS

12V60A

24V30A

INPUT

Voltage

115V - 230V (+/- 15%)

Frequency

50Hz - 60Hz (+/- 10%)

Cos phi

0,9 typ

Efficiency

80% typ

Mains consumption

10A

5A

Fuse

T16A 250V 5x20mm

OUTPUT

Nb of outputs

3 isolated outputs

Nb charging 
curves

4 possible charging curves. 

Selection by external dip-switch

Curves types

IUUo

Charging profile

Summary of Contents for 399050

Page 1: ...EN TECHNICAL MANUAL Battery charger premium 12V60A 399050 PF 15053 premium 24V30A PF 16070...

Page 2: ...to prevent them playing with the device This equipment contains components that may cause electric arcs or sparks when connecting cables for example To prevent any risk of fire or explosion do not ins...

Page 3: ...country of use 4This device is designed to be connected to 220 240V 50Hz or 110 120V 60Hz single phase circuits 115V 230V selection is automatic 4In order to protect the occupants the input point must...

Page 4: ...ce to levels of interference in particular electromagnetic and conducted superior to those legally permitted for example the devise installed too close to an emitter as this may cause irreversible dam...

Page 5: ...thebatterymanufacturer s recommendations Maintenance precautions To prevent any risk of electric shock during maintenance operations ensure that the following recommendations are scrupulously observed...

Page 6: ...that have the same characteristics and performance levels SAFETY PRECAUTIONS 12V60A 24V30A INPUT Voltage 115V 230V 15 Frequency 50Hz 60Hz 10 Cos phi 0 9 typ Efficiency 80 typ Mains consumption 10A 5A...

Page 7: ...motive 3xF15A 32V Automotive Protections Against output overload output short circuit excessive internal temperature excessive battery temperature output overvoltage battery reverse polarity fuse GENE...

Page 8: ...varies from 30 minutes to 4 hours End of Equalisation Green blinking The batteries are almost charged Floating mode will begin in less than 30 minutes Floating Green The batteries are completely char...

Page 9: ...NOT PREMIUM900W 01 CONNECTIONS EN Front LED Main acces TOUCH view_RJ11 CANbus_MicroFit Cycle charge selector UART_RJ12 BAT acces Battery fuses under the product...

Page 10: ...ap using an utility knife Step 3 Pull the conductor through the pre latched strain relief housing Step 4 Open the clamp with a screwdriver and insert the first cable up to the stop Repeat this step fo...

Page 11: ...5 21 Porte du grand Lyon 01707 MIRIBEL CEDEX mdpcontact mdpmotor com Tel 33 04 72 01 83 00 Fax 33 04 72 01 83 09 PLA DATES Ind OPE Propri t MDP ne p Contr le Qualit Instructions particuli res Tol ranc...

Page 12: ...consequently in malfunctions or irreversible damage to the equipment 4Interference with or modifications to the circuit board could result in operating modes not originally anticipated and consequentl...

Page 13: ...ife for environmental reasons At the end of their usable lives all devices must therefore be returned either to the local distributor or entrusted to a specialist electronic equipment recycling compan...

Page 14: ...info dolphin charger com www dolphin charger com...