Your Advantages

•  Suitable for DC charging stations for electric vehicles acc. to 

  IEC/EN 61851-23:2014/AC:2016-06

•  Insulation monitoring according to IEC/EN 61557-8

•   With connection facility of an external coupling device RL 5898 

for voltages up to AC 400 V / DC 500 V or  

RP 5898 for voltages up to AC 690 V / DC 1000 V

•  Very fast reaction time 

 1 s

•  Optimised insulation resistance monitoring also during  

  mains voltage variation 

•  Self-test every full operating hours

•  Preventive fire and system protection

•  Detection of symmetric and asymmetric insulation faults

•  Quick fault localisation through selective earth fault detection to L+  

  and L-

•  Universal application in non-earthed AC, DC, AC/DC networks 

  up to AC max. 250 V or DC max. 300 V

•  Easy adjustment of response values and setting parameter via  

  rotational switch and menu display

•  Suitable for large leakage capacitances up to 5 µF

•  Monitoring also with voltage-free mains

•  Measuring circuit L(+)/L(-) with broken wire detection (can be switched off)

•  Protective conductor PE1/PE2 with broken wire detection  

  (can't be switched off)

Features

•  2 separate adjustable response thresholds  

  (using e.g. for pre-alarm and Alarm)

•  Setting range of 1st response value (Pre-alarm): 20 k

Ω

 … 500 k

Ω

•  Setting range of 2nd response value (alarm): 1 k

Ω

 … 100 k

Ω

•  1 changeover contacts each for insulation failures-Pre-alarm and -alarm

•  Energized or de-energized on trip can be selected for indicator relay
•  Display for indication of measured value, device parameters and  
  device status

•  Automatic and manual device self-test

•  Alarm storage selectable

•  Protection against manipulation by sealable transparent cover

•  External control input for combined test- / reset-button  

  with additional Stop of the measuring function

•  3 wide voltage input for auxiliary voltage

•  Width 52.5 mm

Product Description

The insulation monitor RN 5897/020 of the VARIMETER IMD family provi-
des best and up to date insulation monitoring of modern IT systems in an 
optimum and state of the art way fulfilling the relevant standards. The de-
vice can be used in the most flexible way for AC, DC and AC/DC  systems. 
Mains areas of applications are non-earthed DC charging stations for 
electric vehicles with mains voltages up to DC 1000 V. The adjustment of 
the setting values is simple and user friendly done on 2 rotary switches on 
the front of the device. Via display and LEDs the measured value, device 
parameters and device status are indicated easy to read. With a sealable 
transparent cover the device is protectet against manipulation.

Approvals and Markings

Applications

Insulation monitoring of:

•  Non-earthed AC, DC, AC/DC networks
•  DC charging stations for electric vehicles
•  UPS systems
•  Networks with frequency inverters
•  Battery networks
•  Networks with direct current drives

•  Hybrid and battery-powered vehicles
•  Mobile generator sets

Monitoring Technique

VARIMETER IMD

Insulation monitor
RN 5897/020

Function Diagram

Manual reset

Alarm

Alarm

Pr

e-Alarm

Pr

e-Alarm

Hysteresis function

Reset

21-24

21-24

21-24

21-24

11-14

11-14

11-14

11-14

11-12

11-12

11-12

11-12

Earth fault

E

R

A

R

pA

R

21-22

21-22

21-22

21-22

t

t

Open circuit operation

Open circuit operation

Open circuit operation

Open circuit operation

De-energized on trip

De-energized on trip

De-energized on trip

De-energized on trip

UH

M11593

RN 5897/020

RP 5898

Coupling devices

RL 5898

AC/DC

Canada / USA

1)

 RN 5897 only

Translation

of the original instructions

All Technical Data in this list relate to the state at the moment of edition. We reserve the right
for technical improvements and changes at any time.

Summary of Contents for VARIMETER IMD RL 5898

Page 1: ...tton with additional Stop of the measuring function 3 wide voltage input for auxiliary voltage Width 52 5 mm Product Description The insulation monitor RN 5897 020 of the VARIMETER IMD family provi de...

Page 2: ...relays is frozen and not changed any more If the measurement is disabled the colour of the display changes to orange and the text Stop is displayed Please be aware only the evaluation of the measurem...

Page 3: ...or alarm and pre alarm can be adjusted via 2 rotary switches RA and RpA onthefrontofthedevice Newsettingareimmediately active and do not require a restart of the unit More settings can be done with th...

Page 4: ...y displaying RE k or RE k By pressing the scroll buttons Scroll Up und Scroll Down more measured values can be shown Another value is the mains voltage on L L This is indicated with UN VAC or UN VDC i...

Page 5: ...al tests Advanced Test additional control of indicator relay Display Indication Function Measuring function stopped Error Indication Display Indication Failure cause Failure recovery Broken wire detec...

Page 6: ...rminals PE1 and PE2 must always be connected via separate lines to different terminal points of the protective conductor system The device must not be operated without PE1 PE2 connection nfo Attention...

Page 7: ...eter 4 Power supply type Net Default Ac Parameter 5 Ext coupling device VSG Default oFF Parameter 1 Broken wire detect in measuring circuit BrWiD Broken Wire Detect oFF Parameter 1 Broken wire detect...

Page 8: ...frequency 2 13 2 Hz 13 2 100 Hz acceleration 0 7 gn IEC EN 60068 2 6 Shock resistance 10 gn 11 ms 3 pulses IEC EN 60068 2 27 Climate resistance 30 060 04 IEC EN 60068 1 Terminal designation EN 50005...

Page 9: ...val Variant if required Contacts Type Meas ciruit L1 L2 to PE1 PE2 with coupling device RL RP 5898 RL 5898 RP 5898 Max voltage range UN AC 0 400 V AC 0 600 V DC 0 500 V DC 0 600 V Output voltage at L...

Page 10: ...f type of network AC External coupling device ON RL5898 RP5898 Ungrounded mains RL5898 3 AC 0 440V 40 1000Hz RP5898 3 AC 0 760V 40 1000Hz L1 Ungrounded mains 3N AC 400V 230V 40 1000Hz L2 L3 N RN5897 0...

Page 11: ...97 020 X1 External combined test reset button VSG2 VSG2 X2 11 PE1 12 PE2 14 21 22 24 M11976_a 2 A1 A2 UH 1 L L UN L1 L2 Setting of type of network DC External coupling device ON RL5898 RP5898 Unground...

Page 12: ...12 12 07 21 en 423A E Dold S hne GmbH Co KG D 78120 Furtwangen dold relays dold com www dold com Bregstra e 18 Phone 49 7723 654 0 Fax 49 7723 654356...

Reviews: