18
RK 5942 / 28.01.20 en / 184A
Single channel emergency-stop circuit without feed back loop, with or
without automatic restart.
For automatic restart terminals S12 - S34 must be linked.
No ON-pushbutton necessary.
Suited up to SIL2, Performance Level d, Cat. 3*
)
2-channel emergency-stop circuit without feed back loop, as option with
or without automatic restart.
For automatic restart terminals S12 - S34 must be linked.
No ON-pushbutton necessary.
Suited up to SIL3, Performance Level e, Cat. 4
Application Examples
Single channel emergency-stop circuit without feed back loop, with or
without automatic restart.
For automatic restart terminals S12 - S34 must be linked.
No ON-pushbutton necessary.
Suited up to SIL2, Performance Level d, Cat. 3*
)
Single channel emergency-stop circuit without feed back loop, with or
without automatic restart.
For automatic restart terminals S12 - S34 must be linked.
No ON-pushbutton necessary.
Suited up to SIL2, Performance Level d, Cat. 3*
)
2-channel emergency-stop circuit without feed back loop, as option with or
without automatic restart.
For automatic restart terminals S12 - S34 must be linked.
No ON-pushbutton necessary.
ATTENTION ! When this application is used with RK5942.02, it must
be guarateed that the external circuit on contact 28 has no feedback
influence. I.e. no external voltage must be connected to contact 28.
Suited up to SIL3, Performance Level e, Cat. 4
*
)
Suited up to SIL3, Performance Level e, Cat. 4, when the complete
e-stop circuit is within the same cabinet.
M9232_d
A2
RK5942.03
14
L1(+)
N(-)
emergency
stop
on
A1+
S12
S11
S34
11
13
M9226_c
A2
A1+
S12
S11
S34
13
28
14
L1(+)
N(-)
emergency
stop
on
RK5942.02 + .03
28 by .02
11 by .03
M10965
A2
RK5942.01
28
A1+
ST1
S28+
ST2
13
14
L1(+)
N(-)
on
emergency
stop
M10977
A2
RK5942.01
28
L+
N -
A1+
ST1
S28+
ST2
13
14
on
emergency
stop
M10962_a
A2
RK5942.02 + .03
28 at .02
11 at .03
L1(+)
N(-)
A1+
S12
S11
S34
13
14
on
emergency
stop