Configurable safety system SAFEMASTER PRO - Fieldbus module
15
0265998 / 16.05.19 de / 101A
UG 6954
PR
OFNET
FIELDB
US MODULE UG 6954 (PR
OFINET)
LED 1:
NET
LED 2:
STS
S
TAT
E
MEANING
DESCRIPTION
S
TAT
E
MEANING
DESCRIPTION
OFF
Offline
No po
w
er
No connection
OFF
Not initializ
ed
No po
w
er or module in
State
SETUP
or
NW_INIT
GREEN
Online
(R
UN)
Connection estab
lished
R
UN state
GREEN
Nor
mal oper
ation
Modules off
State NW_INIT
GREEN
Flashing
Online
(Stop)
connection estab
lished
ST
OP state
GREEN
Flashing 1 times
Diagnostic e
vent(s)
Diagnostic e
vent present
GREEN
Flashing 2 times
Blink
Used to identify the
netw
or
k node
RED
Exception
Module in
EXCEPTION state
RED
Flashing 1 times
Configur
ation
error
Identification error
RED
Flashing 2 times
IP address
error
IP address
not configured
RED
Flashing 3 times
Station name
error
Station name
not configured
RED
Flashing 4 times
Inter
nal
error
A ser
ious inter
nal error
has occured