4.4.8 Logical Output step creation
While on the Job modification screen, tap on
LOGICAL OUT
button.
The Logical Out step creation screen will appear.
Select an available output and its type from the list of Outputs.
If an Output was assigned for a specific function in Output settings it is not
available to be used as a logical signal.
There are three types of output signals:
Continous ON
The signal is maintained until it is deactivated in the next
Logical Out step. To deactivate the signal, create a new
Logical Out step and deselect the corresponding signal.
Impulse
The signal is momentary with a defined duration.
Duration of the signal is defined in ms.
Flashing
+
The signal will be blink until it is deactivated in the next
Logical Out step. The time between two flashing signals
is defined in ms in the impulse duration field.
Multiple output signals can be used in the same Logical Out step.
Press the
SAVE
button to save the step, or the
CANCEL
button to quit
programming without saving changes.