E
V
E
N
T
I
N
Source
None (Greys out line)
Local Event
Remote Device Event
Serial
Event
Type
Local:
Keypress
Keypress changed from OFF to ON. The selected ON ACTION will execute.
Keypress changed from ON to OFF. The selected OFF ACTION will execute
GPI
GPI changed from OFF to ON. The selected ON ACTION will execute.
GPI changed from ON to OFF. The selected OFF ACTION will execute
MEM
MEM changed from OFF to ON. The selected ON ACTION will execute.
MEM changed from ON to OFF. The selected OFF ACTION will execute
Sequence Timer
The sequence timer’s time has expired. Only ON ACTION is executed.
The timer automatically restarts for the time period of the next sequence event in the
table. After the last sequence event in the table has expired and its ON ACTION
executed, the timer automatically restarts for the time period of the first sequence event
in the table.
MANUAL EVENT
–
Sequence time is ignored.
Continuous Timer
The Continuous timer’s time has expired. Only ON ACTION is executed.
The timer automatically starts once
“
Save
”
is pressed in the Event Action table. After the
timer has expired and its ON ACTION executed, the timer automatically restarts for the
time period setup in the Event Action table.
Remote:
AHSC Receive Event
A successful pattern match has occurred for the selected AHSC Receive Event pattern
on the selected Remote Device. Only ON ACTION is executed.
If the AHSC Receive Event pattern is assigned to multiple Remote Devices, only the
ON ACTION associated with the Remote Device that received the successful match will
execute.
GTP-32/DC20 Receive
( Only available for Device Type “GTP-32/DC20”)
An Event Label was received that matched the selected GTP-32/DC20 Event Label on
the selected Remote Device. Only ON ACTION is executed.
If an Event Label is assigned to multiple Remote Devices, only the ON ACTION
associated with the sending Remote Device will execute.
USP Keypress
( Only available for Device Type “USP”)
An event (Keypress or GPI) was received that matched the selected event on the
selected Remote Device.
Event
GPI Number, AHSC Receive Event Label, Ethernet Receive Event Label, or GTP-32/DC20 Event
Label, Sequence Timer time period.
The display labels in the drop down menus are the same user entered labels on the event web pages