XTLplus International Series Installation and Programming Guide
Digital Monitoring Products
15
Receiver 2 Programming
Allows you to set the options for the second receiver the panel attempts to contact
when sending reports. The XTLplusINT supports communication to two receivers. If
you select
YES
for any of the Receiver 2 options, you must have at least one IP address
programmed in Receiver 2 programming. Receiver 2 defaults are set to
NO
.
Receiver 2 Backup?
Select NO to allow Receiver 2 to send dual messages to the central station. Select YES
to allow Receiver 2 to start receiving messages only when Receiver 1 stops working, and
to return to its backup state when Receiver 1 returns to its normal state. The default is
NO
.
Alarm Reports
YES enables Abort, Alarm, Alarm Restoral, Alarm Bell Silenced, Ambush, Exit Error, and
System Recently Armed reports to be sent to this receiver. Default is
NO.
Supervisory/Trouble Reports
YES enables Supervisory, Trouble, Trouble Restoral, Force Armed, Late to Close, and
Fault reports to be sent to this receiver. Default is
NO
.
Opening/Closing and User Reports
YES enables Opening/Closing, Code Changes, and Bypass reports by user to be sent to
this receiver. Default is
NO
.
Test Report
YES
enables the Recall Test report to be sent to this receiver. Default is
NO
.
First IP Address
Enter the first (primary) IP address where the panel sends network or cellular
information. Enter all 12 digits and leave out the periods. For example, enter IP address
192.168.0.250 as 192168000250. The periods display automatically.
The message is sent using first Cell APN and the first IP Address. If no acknowledgment
is received, first Cell APN and the second IP address are used, followed, if needed, by
second Cell APN and first and second IP addresses, respectively.
First IP Port
Enter the first IP port number to be used in conjunction with the First IP Address. The
IP port identifies the port used to communicate messages to and from the panel. The
default IP Port setting is
2001
.
Second IP Address
Enter the second (secondary) IP address where the panel sends network or cellular
information. Enter all 12 digits and leave out the periods. For example, enter IP address
192.168.0.250 as 192168000250. The periods display automatically.
Second IP Port
Enter the second IP port number to be used in conjunction with the second IP Address.
The IP port identifies the port used to communicate messages to and from the panel.
The default IP Port setting is
2001
.
RECEIVER 2 PROG
BACKUP?
NO
YES
ALARM
NO
YES
SPV/TRBL NO
YES
O/C USER
NO
YES
TEST RPT
NO
YES
FIRST IP ADDR
000.000.000.000
FIRST IP PORT
2001
SECOND IP ADDR
2001
SECOND IP PORT
2001