HOW-TO INSTRUCTIONS
LT-1225 © 2017 Digital Monitoring Products, Inc.
17072
734N How-To Programming Instructions
To program a 734N, you must complete the programming process in two places: the panel and the 734N. This guide
walks you through programming the 734N into an XR150/XR550 Series panel and then programming the 734N itself.
Program the XR150/XR550 Series Panel
1. Momentarily place a jumper over both pins on the panel’s RESET header.
2. Enter the code 6653 (PROG) and press CMD.
3. The keypad displays PROGRAMMER. Press any select key or area.
4. Press CMD until NETWORK OPTIONS. Press any select key or area.
5. CMD through the options until LOCAL IP ADDRESS is displayed.
6. Write down the LOCAL IP ADDRESS of the panel to use when programming the 734N module.
7. CMD through the options until 734N LISTEN PORT is displayed.
8. Enter the port number that the 734N will use to send communication to the panel. Default is 2002. Write
down the port number, as this must be the same port that is programmed in PANEL IP PORT within the 734N
COMMUNICATION programming menu. Press CMD to display 734N Passphrase.
Note:
The 734N LISTEN PORT cannot be the same as the panel network programming port.
9. Enter an 8 to 16-character passphrase to encrypt communication with the 734N module. The 734N passphrase
must match the 734N passphrase entered in COMMUNICATION programming of the 734N.
Note:
A passphrase is required for communication to occur with the panel.
10. Exit NETWORK OPTIONS and CMD to DEVICE SETUP.
11. Enter the device number of the 734N you are programming. For example, a 734N with an address of 505 on
AX500 would represent Door 505 and zones 505-508. See Table 1 for device addresses and zones.
Note:
XR150 Series panels only support addresses 2-8.
Table 1: Device Addresses and 734N Zone Numbers
Device/
Door
Zones
Device/
Door
Zones
Device/
Door
Zones
Device/
Door
Zones
Device/
Door
Zones
Device/
Door
Zones
501
501-504
601
601-604
701
701-704
801
801-804
901
901-904
2
21-24
505
505-508
605
605-608
705
705-708
805
805-808
905
905-908
3
31-34
509
509-512
609
609-612
709
709-712
809
809-812
909
909-512
4
41-44
513
513-516
613
613-616
713
713-716
813
813-816
913
913-916
5
51-54
517
517-520
617
617-620
717
717-720
817
817-820
917
917-920
6
61-64
521
521-524
621
621-624
721
721-724
821
821-824
921
921-924
7
71-74
525
525-528
625
625-628
725
725-728
825
825-828
925
925-928
8
81-84
529
529-532
629
629-632
729
729-732
829
829-832
929
929-932
9
91-94
533
533-536
633
633-636
733
733-736
833
833-836
933
933-936
10
101-104
537
537-540
637
637-640
737
737-740
837
837-840
937
937-940
11
111-114
541
541-544
641
641-644
741
741-744
841
841-844
941
941-944
12
121-124
545
545-548
645
645-648
745
745-748
845
845-848
945
945-948
13
131-134
549
549-552
649
649-652
749
749-752
849
849-852
949
949-952
14
141-144
553
553-556
653
653-656
753
753-756
853
853-856
953
953-956
15
151-154
557
557-560
657
657-660
757
757-760
857
857-860
957
957-960
16
161-164
561
561-564
661
661-664
761
761-764
861
861-864
961
961-964
12. Enter a device name. To add a device name, press any select key or area. The default device name (DEVICE x)
displays. Select CMD to accept the default name or press a select key or area to enter a new name (up to 32
alphanumeric characters). Press CMD when finished.
13. Based on the device number, the DEVICE TYPE may be assumed. Device 501 or higher will automatically be
selected as a DOOR device type.
14. For DEVICE COMMUNICATION TYPE, select the blank select key or area and then select NETWORK.
15. Exit DEVICE SETUP. CMD through options until STOP. Exit programming.