4
7360/7363 Installation and Programming Guide | Digital Monitoring Products, Inc.
Wire the Keypad
The 7360 and 7363 keypads are supplied with a 4-wire harness for panel keypad bus
connection. Since all 7300 Series keypads operate together on the Keypad bus using
the same address, there is no address option to set.
Observe wire colors when connecting the Red, Yellow, Green, and Black wires to the
keypad bus.
When wiring directly to the panel terminals:
1.
Connect Red to panel terminal 7.
2. Connect Yellow to terminal 8.
3. Connect Green to terminal 9.
4. Connect Black to terminal 10.
2
Install the System Information Reference Card
User Code instructions are on one side of the card and the opposite side offers an
area to record zone numbers and names. Figure 3 shows the location of the pull-out
card holder on the back of the keypad.
While the keypad is attached to the wall, insert the bottom of the card at an angle to
align the card into the bottom slot, then slide the card in place.
3
Mount the Keypad
All DMP keypad housings are designed to easily install on any 4” square box, 3-gang
switch box, DMP 695 and 696 backbox, or flat surface.
4