background image

InstallatIon sheet 

893A Dual Phone Line Module

Description

The 893A is a dual telephone line supervision module that allows DMP Panels to indicate a phone line failure to the 

premises and central station, and switch to secondary phone line communication when the primary line is down.

Compatibility

The 893A is compatible with XR100/XR500 and XR150/XR350/XR550 Series Panels.

Phone Line Monitor

The 893A uses a phone line monitor for the main and backup phone lines. Before sending a report, the 893A verifies 

that the main phone line is working. If the line is bad, the module tests the backup phone line. The 893A sends the 

report on the first working phone line.

The phone line monitor has a two-minute trouble delay and a one-minute restore delay. Phone line trouble is 

displayed in the keypad Status List as a System Trouble. At least one keypad on the system must be programmed to 

display system troubles in the Status List.

Two Line Digital Dialer

You can configure the 893A to provide two lines of digital dialer for XR100/XR500 and XR150/XR350/XR550 Series 

panels. The MAIn modular jack is used for the primary dialer. The BAckuP modular jack is used for the secondary 

digital dialer line.

CAUTION -

 To reduce the risk of fire, use only No. 26 AWG or larger telecommunication line cord, such as DMP Model 

356 Series Phone Cords.

Processor Fail Buzzer

The 893A Module also monitors the panel cPu and sounds a trouble buzzer whenever the panel processor is reset 

using J16 or the processor stops functioning. The 893A Module also monitors the keypad bus and sounds a trouble 

buzzer whenever the keypad bus fails to operate.

Jumper Settings

There are two sets of jumpers on the 893A Module. For Digital Dialer, set 

both 

jumpers, J1 and J2, to DD. Refer to 

Figure 1 for jumper locations.

Figure 1: 893A Layout

893A J4 MAIN

to Phone Block

893A J5 BACKUP

to Phone Block

893A P3 PANEL

to Panel J3 Phone Line Connector

DS1

Buzzer

PANEL

P3

MAIN

BACKUP

J4

J5

F2

F1

J1

DD

MPX

K4

K3

J2

DD

MPX

K2

P10

893A P10 

connector

to Panel J10

connector