734 Installation and Programming Guide | Digital Monitoring Products
11
PROGRAM THE PANEL
To access the Programmer menu, reset the panel, enter
6653
(PROG), then press
CMD
.
After completing each of the following steps, press
CMD
to advance to the next option. Refer to the panel
programming guide as needed.
DEVICE SETUP
Advance to
DEVICE SETUP
, then press a select area or top row key to enter the setup
menu.
Device Number
Set the module’s address. For information about valid addresses, refer to Table 2.
Device Name
Press any select area or top row key, then enter a name for the module.
Device Type
Press any select area or top row key, then select
DOOR
as the device type.
Communication Type
If the module is connected to the Keypad Bus, select
KPD
(Keypad Bus). If the
module is connected to the AX-Bus, select
AX-BUS
. Press any select area or top row
key to display available options.
Configure additional options as needed. To configure specific options for the module locally, do not program
CARD
OPTIONS
or
734 OPTIONS
in Device Setup.
DEVICE SETUP
DEVICE SETUP
DEVICE NO: -
DEVICE SETUP
*UNUSED*
DEVICE SETUP
TYPE:
DOOR
DEVICE SETUP
COMM TYPE:
AX-BUS