Digital Monitoring Products, Inc. | 714N-POE Installation and Programming Guide
9
PROGRAM START DISPLAY
When you connect the keypad to the module, the version number
and release date display. Press
6653
(PROG) then
CMD
to enter the
Programming Menu.
INITIALIZATION OPTION
These options can set the 714N-POE module programming memory
back to factory defaults. Press any select key or area to enter the
initialization menu.
INITIALIZE CONFIRM OPTION
The module displays
SURE? YES NO
for confirmation to clear
the memory. This is a safeguard against accidentally erasing the
programming. No memory is cleared from the programming until you
answer
YES
to the
SURE?
option. Selecting
NO
leaves communication
options unchanged.
COMMUNICATION MENU
Press any select key or area to enter the Communication menu. Select
NET as the communication type.
714N PROGRAMMING
VER VVV MM/DD/YY
INITIALIZE ALL?
NO YES
ARE YOU SURE?
YES NO
714N
COMMUNICATION