8.4.
Operating states
The following operating states are possible for the DLoG MPC 6:
Status of internal LEDs
Power (green)
Temp (red)
DLoG MPC 6 status
OFF OFF
Initial state, idle time - waiting for a new ignition
signal after switch off; no power supply
OFF FLASHING
Temperature sensor malfunctioning
OFF ON
Heating is on at temperatures < 0 °C, or
overheating warning at temperatures > 62 °C.
The computer will not start until the temperature
inside the unit is between 0 and 62 °C again.
ON OFF
Computer is starting up; normal operational
state; shutdown delay time is running
ON
ON
Temp. < -25°C or Temp. > 70°C
ON
FLASHING
Temperature sensor malfunctioning;
automatic shutdown software configuration