background image

120 Glasgow Avenue

Inglewood, California 90301

U.S.A.

Request to Exit

(Free Exit)

Card Reader

DK Prox Reader

Wiegand Access

Control Device

26, 30, 31-Bit Wiegand

Single Board Enclosure with

Built-In Card Reader and Lighting

DK Prox Reader - P/N 1815-333

HID Reader - P/N 1815-392

AWID Reader - P/N 1815-292

Single Board Enclosure

P/N 2351-080

Quad Board Enclosure

P/N 2351-081

Door Lock Control

Power for electric 

strike or magnetic 

lock is NOT 

provided by the 

board. Use 

separate UL listed 

power supply.

6 conductor, stranded with overall 

shield, 18-22 gauge. 500 ft max.

DO NOT use twisted pair.

Maglock

Electric 

strike

#20-Card Reader LED

OR Beeper Control

(Available on certain

card readers)

Gate Operator Control

Board Power

16.5 VAC, 20 VA

Required

18 GA. Wire 100 ft max
16 GA. Wire 200 ft max

34

33

32

31

30

29

28

27

26

25

24

23

22

21

14

15

16

17

18
19

20

13

12

11

10

9

8

7

6

5

4

3

2

1

ON

1

0

BOARD ADDRESS

0

9

8

7

6

5

4 3 2

1

NC

OUTPUT

RELAY

NO

NC

ALARM

RELAY

NO

NC

AUX

RELAY

NO

ENT

RESET

2358-010

RF

DATA

RF

SECURE

RF

STATUS

CODE

SENT

CODE

GOOD

CODE

BAD

34

33

32

31

30

29

28

27

26

25

24

23

22

21

14

15

16

17

18
19

20

13

12

11

10

9

8

7

6

5

4

3

2

1

ON

1

0

BOARD ADDRESS

0

9

8

7

6

5

4 3 2

1

NC

OUTPUT

RELAY

NO

NC

ALARM

RELAY

NO

NC

AUX

RELAY

NO

ENT

RESET

2358-010

RF

DATA

RF

SECURE

RF

STATUS

CODE

SENT

CODE

GOOD

CODE

BAD

NC

NO

RING

ON

CLK

SEN

SPK

VOL

FEED

BACK

RS 232

ELEVATOR

12

34

56

78

9

10

11

12

13

14

1
2
3

MIC

VOL

OFF

KEYPAD

3 2 1

3 2 1

3

2

1

MASTER

CODE

16AC

16AC

BAT

1NO

1NC

1C

2RY

2C

A

Z

IMC

5VDC

IMD

SPKR

COM

MIC

PSW

CGND

PHONE

1

2

3

4

20

19

18

17

16

15

14

13

12

11

10

9

8

7

6

5

NO NC

C

Access Control

System Board

Tracker Expansion

Board Address 3

Tracker

Expansion

Board

Address 4

Relay 2

Communication 2

Communication Line

Tracker Expansion Board Enclosure Options

Typical BASIC Tracker

Expansion Board

Wiring Options

for Access Point

NO “optional” tracker features or battery back-up wiring shown, see manual for details.

Auxiliar

y T

erminal

Relay 0

Relay 1

Central Office 

phone line - 

touch tone, 

loop start.

Switch closure across 

terminals 4 & 6 will 

activate relay 1 for its 

programmed strike time.

(Postal Lock)

Important Note: Relay 2 is used to 

control tracker expansion board 

addresses 3-10, Relay 1 or Relay 0 can 

be used as the Primary Relay that will 

open a visitor door or gate when the 

resident pushes “9” on their telephone.

Tracker Expansion Board Notes:

All tracker expansion boards can be wired with 

desired options for their access points like shown on  

tracker expansion board address 3.

Communication line will continue for each board like 

shown on tracker expansion board address 4.

Board addresses MUST start at 3 and contiunue thru 

board address 10 (up to

12 boards using Zone 

Addresses) if required.

Tracker expansion boards connected to Wiegand 2 will activate 

Relay 2 in the access control system.

Main Door/Gate

Relay 1 or Relay 0

Auxiliary

Terminal

Black #9-Com

White #8-Data 1

Green #7-Data 0

Black #27-Com

White #28-Data 

1

Green #29-Data 

0

Black #27-Com

White #28-Data 

1

Green #29-Data 

0

Green #29-Data 

1

White #28-Data 

0

Black #27-Com

Brown #19

Brown #19

To #18

To #18

Blue #17

Blue #17

Red #10

Tracker Expansion

Board “Busy” #10

Red #10

Output Relay

#25 & #26

Brown #13

Blue #14

To Board Addresses 5 thru 10

Ground #32

Set Output

Relay Jumper

Relay 2

Jumper

Relay

Jumper

Relay

Jumper

N.O.

Com

To #8 Com

To #8

Ground

12 GA. Wire

Aux

Power

Main

Power

Power #33

Power #34

Blue - Beeper

Yellow - LED

Board Power

Ground #32

Ground

Power #33

Power #34

#10 connects

ONLY to tracker

expansion boards

NC

NO

First Board Address

Starts at 3

ON

OFF

1

0

BOARD ADDRESS

0

9

8

7

6

5

4

3

2

1

Switch MUST be ON (1) 

for board address 10.

Switch MUST be OFF (0)

for board addresses 3 thru 9.

Second Board Address

Set to 4

Board Address 10

Setting

ON

OFF

1

0

BOARD ADDRESS

0

9

8

7

6

5

4

3

2

1

#6-Green = Data 0
#7-White = Data 1

#8-Black = Common

#9-Red = 12 VDC Power

Relay

Jumper

NO

OUTPUT

RELA

Y

NC

NO

OUTPUT

RELA

Y

NC

NO

OUTPUT

RELA

Y

NC

NO

OUTPUT

RELA

Y

NC

EXIT

PUS

H TO

Relay 

2

Jumper

IMPORTANT: The maximum distance for a tracker expansion board HARDwire run is 4000 feet TOTAL (1 to 12 boards 

can be in a HARDwire run). The farthest board can be NO more than 2000 feet away from the access control system.

See manual for multiple tracker expansion boards layout limitations.

Up to 12 tracker expansion boards can be HARDwired to relay 2/wiegand 2 at the access control system.

OR

ON

OFF

1

0

BOARD ADDRESS

0

9

8

7

6

5

4 3 2

1

For COMPLETE installation instructions, please refer to the HARDwired Installation/Owner’s manual P/N 2358-065.

Lock

Power

Card Reader

Electric Strike

Door Lock

Black #27-Com

White #28-Data 

1

Green #29-Data 

0

OR

Request to Exit

(Free Exit)

EXIT

PUS

H TO

Use 6 conductor stranded with overall shield. 18 - 22 gauge. 

ONLY use 18 gauge when wiring more than 8 boards.

DO NOT connect shield to 2358-010 board common.

DO NOT use twisted pair.

Note: If card 

reader has 

additional 

lighting for 

outdoor use, 

separate power 

must be 

provided.     

QUICKSTART “BASIC” HARDWIRE TRACKER EXPANSION BOARD TO RELAY 2/WIEGAND 2 GUIDELINES