background image

H-SW3000 USER MANUAL V1

 

  < 11 > 

6

 

TECHNICAL INFORMATION

 

6.1

 

Maintenance 

To avoid the H-SW3000 clogging, after every 40 hours of continuous operation, use a detergent composed of 35% vinegar and 65% distilled 
water through the system and fog 10-15 times after finish heating-up to prevent the accumulation of particulate matter in the heating 
element.  

The recommended cleaning procedure is as follows. 

1)

Unplug the product from power.

2)

Empty all fluid from the machine.

3)

Add cleaning solution to the tank.

4)

Connect the product to power and allow it to heat up.

5)

Run the product in a well-ventilated area until the tank is empty. Do not allow the pump to run dry.

6)

Refill with fog fluid to continue using the H-SW3000. Run the machine briefly to clear any cleaning solution from the pump and 
heater. 

7)

Excessive dust, fluid residue and dirt will degrade performance and cause overheating. Remove dust from air vents with air 
compressor, vacuum or soft brush. The casing could be cleaned by the damp cloth. 

Test-

run your DJPOWER® 

H-SW3000 on a monthly basis to achieve the best performance. 

6.2

 

Storage  

6.2.1

 

Machine Storage 

Before storing the machine, clean it as described in the cleaning procedure above; however, only follow steps 1 through 5. Do not refill the 
tank with fog fluid if storing the machine. Cleaning the system prior to storage will help prevent any particles from condensing inside the 
pump or heater while not in use.  

6.3

 

Trouble

s

hooting  

Errors 

Symptom 

Potential Cause 

Remedies 

No fluid 

R

efer  to  “MENU  MAP”  chapter  to  for  more 

information 

No fluid 

Refill fluid 

Fluid pump error 

Contact Service

 

Low water 

R

efer  to  “MENU  MAP”  chapter  to  for  more 

information 

Low water 

Refill water 

Water pump error 

Contact Service

 

Heat failure 

R

efer  to  “MENU  MAP”  chapter  to  for  more 

information 

Contact Service

 

Water Auto-refill 

Summary of Contents for H-SW3000

Page 1: ......

Page 2: ......

Page 3: ...ETTING THE BREAKER 6 4 4 DMX LINKING 6 4 5 MOUNTING 6 4 5 1 Orientation 6 4 5 2 Rigging 6 5 OPERATION 7 5 1 PREPARING FOR OPERATION 7 5 2 ON DEVICE CONTROL PANEL 7 5 3 ON DEVICE CONTROL MODE OPERATION 7 5 3 1 Programming 7 5 3 2 Menu Map 7 5 4 DMX MODE OPERATION 9 5 4 1 Starting Address 9 5 4 2 DMX Mode Menu Map 9 5 4 3 DMX Channel Assignments and Values 9 5 5 AUTO RUN LAST SETTINGS 10 5 6 FLUID S...

Page 4: ......

Page 5: ...tion Useful information 1 4 Disclaimer The information and specifications contained in this User Manual are subject to change without notice DJPOWER assumes no responsibility or liability for any errors or omissions and reserves the right to revise or to create this manual at any time Copyright 2018 DJPOWER All rights reserved 1 5 Safety Notes Please read the following Safety Notes carefully befor...

Page 6: ...tion Do not operate this product if you see damage to the housing or cables Have the damaged parts replaced by an authorized technician at once Make sure there are no flammable materials close to this product while it is operating Do not cover or plug the output nozzle during operation Do not use the product as a space heater Never carry the product by the power cord or any moving part Always use ...

Page 7: ...ion Advanced No Water protection Anti loose power plug Low fluid consumption 3 5L fluid reservoir 2 hours on full output Built in LCD control 3 pin and 5 pin DMX control Please use DJPOWER professional fluid PRO V PRO A PRO C different fluid will show different stage effect DJPOWER PRO V fog fluid provides an awesome Quick Dissipation effect 2 3 Product Overview Dual Nozzle Bracket Rain proof Shie...

Page 8: ...H SW3000 USER MANUAL V1 4 2 4 Product Dimensions 885 mm 500 mm 455 mm 3 pin DMX Socket 5 pin DMX Socket Power Input for Electronics Power Switch LCD Control Board Breaker ...

Page 9: ...ut Duration full volume 100 0 min Features Physical Thermostat Electronic Thermo Control Adjustable Output Adjustable Fan Speed No Fluid Protection Control On device Manual Control LCD control board Wireless Control Wired Control Control Protocol DMX 512 DMX Channel Range 3 Data Connectors 3 and 5 pin XLR Accessory Diversion Hose 2 pc 3 m 125mm 5 inch Diversion Nozzle Optional 125mm 5 inch Consuma...

Page 10: ...pressing the button with your finger Plug the product s power cord into the power outlet and continue using as recommended 4 4 DMX Linking You can link the H SW3000 to a DMX controller using a 3 or 5 pin DMX connection If using other DMX compatible products with this product you can control each individually with a single DMX controller Instructions for connecting and configuring this product for ...

Page 11: ...E triggers the pump to modify the output volume STOP Enter enables the currently displayed menu or sets the currently selected value into the selected function STOP turns the fog output off 5 3 On device Control Mode Operation 5 3 1 Programming Refer to the Menu Map to understand the menu options The menu map shows the main level and a variable number of programming levels for each option To go to...

Page 12: ...o set fan speed of VOLUME mode 1 100 Humidity 100 Press or to set output humidity of VOLUME mode OFF 25 50 75 100 Timer Interval 600s Press or to set timer interval of TIMER mode 5 600s Timer Duration 300s Press or to set timer duration of TIMER mode 5 300s DMX Address 512 Press or to select DMX starting address 1 512 Fluid Sensor ON Press or to activate deactivate fluid sensor to turn on off no f...

Page 13: ... the starting address in the 001 512 DMX range and uses 3 DMX channels which defines the highest configurable address to 510 to have all channels controllable Connect a DMX cable from the DMX output of the DMX controller to the DMX input socket on the product or press repeatedly MENU button until the LCD shows DMX Address Press or to set desired DMX starting address 5 4 2 DMX Mode Menu Map When co...

Page 14: ...l operable only keep flickering 5 6 2 Clear No Fluid Protection Warning When the machine is under the no fluid protection after refilling the fluid there are three ways to clear the warning Press STOP first then press VOLUME to let the machine run again the warning will disappear until the fluid is pumped and fill the tube Under the DMX control mode bring down channel 1 to OFF value 0 9 then back ...

Page 15: ...ust fluid residue and dirt will degrade performance and cause overheating Remove dust from air vents with air compressor vacuum or soft brush The casing could be cleaned by the damp cloth Test run your DJPOWER H SW3000 on a monthly basis to achieve the best performance 6 2 Storage 6 2 1 Machine Storage Before storing the machine clean it as described in the cleaning procedure above however only fo...

Page 16: ......

Reviews: