H-SW3000 USER MANUAL V1
< 10 >
5.5
Auto Run Last Settings
If the machine is shut off while it is operating at standalone mode (On-device & Wireless control)
, the “Auto Run Last Setting” will allow the
machine to recover its previous same operating status when the unit is powered on again without pressing any button.
•
Shut off: Get disconnected from power source, or turn off the power switch
•
Power on: Get connected with power source, or turn on the power switch
5.6
Fluid Sensor
This machine uses software-based fluid sensor to detect whether there is fluid inside tube so as to protect the pump from being damaged.
Turn on the
“
Fluid Sensor
”
to activate
“
No Fluid Protection
”
function.
Fluid Sensor
ON
5.6.1
Trigger
“
No-Fluid Protection
”
When the Fluid Sensor is ON, the software-based
“
no-fluid protection
”
function will be activated. After the program continues to detect the
machine working with no fluid inside the tube for 90 s, the pump-shutoff will be activated with the flickering warning page showing on the
screen.
Fog Fluid Low
Refill
When this waring message shows up, the machine will stop work but the LCD is still operable, only keep flickering.
5.6.2
Clear
“
No-Fluid Protection
”
Warning
When the machine is under the no-fluid protection, after refilling the fluid, there are three ways to clear the warning.
•
Press<STOP>
first, then press<VOLUME>
to let the machine run again, the warning will disappear until the fluid is pumped and
fill the tube.
•
Under the DMX control mode, bring down channel 1 to OFF (value 0-9), then back to ON (value 10-255), to let the machine run again.
The warning will disappear until the fluid is pumped and fill the tube.
•
Turn off
“
Fluid Sensor
”
in the menu.
The LCD will keep flickering whenever it shows the warning message or regular operation menu pages until the fluid is finally pumped into
tube and sensed by software.
5.7
Low Water Protection
When the water in the chamber is low, the LCD will flicker and show the warning message as below:
Water Level Low
Refill Water
After the warning message shows up, the machine can still run for another 10 minutes with remaining water in the chamber, then
shut off. Adding water in the chamber by either opening the lid on the top, or through the water auto-refill inlet.
Fog output is no need to stop when open the water chamber lid, the big volume of fog will not come out towards to people
from the open lid.
Water auto-refill: please use jumper hose to avoid spill.