background image

                                                                                                                                                       

H-SW3000 USER MANUAL V1

 

< 10 > 

5.5

 

Auto Run Last Settings 

If the machine is shut off while it is operating at standalone mode (On-device & Wireless control)

, the “Auto Run Last Setting” will allow the 

machine to recover its previous same operating status when the unit is powered on again without pressing any button.  

 

Shut off: Get disconnected from power source, or turn off the power switch  

 

Power on: Get connected with power source, or turn on the power switch  

5.6

 

Fluid Sensor 

This machine uses software-based fluid sensor to detect whether there is fluid inside tube so as to protect the pump from being damaged. 
Turn on the 

Fluid Sensor

 to activate 

No Fluid Protection

 function. 

Fluid Sensor 
            ON 

5.6.1

 

Trigger 

No-Fluid Protection

  

When the Fluid Sensor is ON, the software-based 

no-fluid protection

 function will be activated. After the program continues to detect the 

machine working with no fluid inside the tube for 90 s, the pump-shutoff will be activated with the flickering warning page showing on the 
screen.  

 Fog Fluid Low 

Refill 

When this waring message shows up, the machine will stop work but the LCD is still operable, only keep flickering.  

5.6.2

 

Clear 

No-Fluid Protection

 Warning  

When the machine is under the no-fluid protection, after refilling the fluid, there are three ways to clear the warning. 

 

Press<STOP>

 first, then press<VOLUME>

 to let the machine run again, the warning will disappear until the fluid is pumped and 

fill the tube. 

 

Under the DMX control mode, bring down channel 1 to OFF (value 0-9), then back to ON (value 10-255), to let the machine run again. 
The warning will disappear until the fluid is pumped and fill the tube. 

 

Turn off 

Fluid Sensor

 in the menu. 

The LCD will keep flickering whenever it shows the warning message or regular operation menu pages until the fluid is finally pumped into 
tube and sensed by software.  

5.7

 

Low Water Protection 

When the water in the chamber is low, the LCD will flicker and show the warning message as below:  

Water Level Low 

Refill Water 

After the warning message shows up, the machine can still run for another 10 minutes with remaining water in the chamber, then 
shut off. Adding water in the chamber by either opening the lid on the top, or through the water auto-refill inlet.

  

Fog output is no need to stop when open the water chamber lid, the big volume of fog will not come out towards to people 
from the open lid.  

Water auto-refill: please use jumper hose to avoid spill. 

Summary of Contents for H-SW3000

Page 1: ......

Page 2: ......

Page 3: ...ETTING THE BREAKER 6 4 4 DMX LINKING 6 4 5 MOUNTING 6 4 5 1 Orientation 6 4 5 2 Rigging 6 5 OPERATION 7 5 1 PREPARING FOR OPERATION 7 5 2 ON DEVICE CONTROL PANEL 7 5 3 ON DEVICE CONTROL MODE OPERATION 7 5 3 1 Programming 7 5 3 2 Menu Map 7 5 4 DMX MODE OPERATION 9 5 4 1 Starting Address 9 5 4 2 DMX Mode Menu Map 9 5 4 3 DMX Channel Assignments and Values 9 5 5 AUTO RUN LAST SETTINGS 10 5 6 FLUID S...

Page 4: ......

Page 5: ...tion Useful information 1 4 Disclaimer The information and specifications contained in this User Manual are subject to change without notice DJPOWER assumes no responsibility or liability for any errors or omissions and reserves the right to revise or to create this manual at any time Copyright 2018 DJPOWER All rights reserved 1 5 Safety Notes Please read the following Safety Notes carefully befor...

Page 6: ...tion Do not operate this product if you see damage to the housing or cables Have the damaged parts replaced by an authorized technician at once Make sure there are no flammable materials close to this product while it is operating Do not cover or plug the output nozzle during operation Do not use the product as a space heater Never carry the product by the power cord or any moving part Always use ...

Page 7: ...ion Advanced No Water protection Anti loose power plug Low fluid consumption 3 5L fluid reservoir 2 hours on full output Built in LCD control 3 pin and 5 pin DMX control Please use DJPOWER professional fluid PRO V PRO A PRO C different fluid will show different stage effect DJPOWER PRO V fog fluid provides an awesome Quick Dissipation effect 2 3 Product Overview Dual Nozzle Bracket Rain proof Shie...

Page 8: ...H SW3000 USER MANUAL V1 4 2 4 Product Dimensions 885 mm 500 mm 455 mm 3 pin DMX Socket 5 pin DMX Socket Power Input for Electronics Power Switch LCD Control Board Breaker ...

Page 9: ...ut Duration full volume 100 0 min Features Physical Thermostat Electronic Thermo Control Adjustable Output Adjustable Fan Speed No Fluid Protection Control On device Manual Control LCD control board Wireless Control Wired Control Control Protocol DMX 512 DMX Channel Range 3 Data Connectors 3 and 5 pin XLR Accessory Diversion Hose 2 pc 3 m 125mm 5 inch Diversion Nozzle Optional 125mm 5 inch Consuma...

Page 10: ...pressing the button with your finger Plug the product s power cord into the power outlet and continue using as recommended 4 4 DMX Linking You can link the H SW3000 to a DMX controller using a 3 or 5 pin DMX connection If using other DMX compatible products with this product you can control each individually with a single DMX controller Instructions for connecting and configuring this product for ...

Page 11: ...E triggers the pump to modify the output volume STOP Enter enables the currently displayed menu or sets the currently selected value into the selected function STOP turns the fog output off 5 3 On device Control Mode Operation 5 3 1 Programming Refer to the Menu Map to understand the menu options The menu map shows the main level and a variable number of programming levels for each option To go to...

Page 12: ...o set fan speed of VOLUME mode 1 100 Humidity 100 Press or to set output humidity of VOLUME mode OFF 25 50 75 100 Timer Interval 600s Press or to set timer interval of TIMER mode 5 600s Timer Duration 300s Press or to set timer duration of TIMER mode 5 300s DMX Address 512 Press or to select DMX starting address 1 512 Fluid Sensor ON Press or to activate deactivate fluid sensor to turn on off no f...

Page 13: ... the starting address in the 001 512 DMX range and uses 3 DMX channels which defines the highest configurable address to 510 to have all channels controllable Connect a DMX cable from the DMX output of the DMX controller to the DMX input socket on the product or press repeatedly MENU button until the LCD shows DMX Address Press or to set desired DMX starting address 5 4 2 DMX Mode Menu Map When co...

Page 14: ...l operable only keep flickering 5 6 2 Clear No Fluid Protection Warning When the machine is under the no fluid protection after refilling the fluid there are three ways to clear the warning Press STOP first then press VOLUME to let the machine run again the warning will disappear until the fluid is pumped and fill the tube Under the DMX control mode bring down channel 1 to OFF value 0 9 then back ...

Page 15: ...ust fluid residue and dirt will degrade performance and cause overheating Remove dust from air vents with air compressor vacuum or soft brush The casing could be cleaned by the damp cloth Test run your DJPOWER H SW3000 on a monthly basis to achieve the best performance 6 2 Storage 6 2 1 Machine Storage Before storing the machine clean it as described in the cleaning procedure above however only fo...

Page 16: ......

Reviews: