H-6 PRO FOG MACHINE
injection.
First reason: Using the low quality or counterfeit fog fluid, low quality fog fluid
have more impurities, easy to adhere to the pipe wall and hindered.
First reason: Using the low quality or counterfeit fog fluid, low quality fog fluid
have more impurities, easy to adhere to the pipe wall and hindered temperature
transmission result in incomplete atomization caused fluid injection.
Second reason: using an incorrect fog fluid. Different fog fluid have different
required atomization temperature. If you use the wrong fog fluid result in oil
cannot fully atomization caused oil injection.(fig 1)
B. Heater blocking trouble
:
poor atomization fluid injection is the early signs of
heater block. Using poor quality fog fluid or not timely maintenance cleaning
the fog machine for a long time. Inevitable will appear the terminal symptom of
heater blocking.
Reason: heater blocked is because used inferior fog fluid or not maintenance
for a long time. Have nothing to do with the quality of machine. Like a car with
poor quality gasoline produce poor fluid circuit failure or long-time no
maintenance the car will inevitably appear bigger problems. (fig 2)
C. Solutions to these problems: fog machine heating pipes used for a long time
and then the pipe wall will easily produce sediments (The more inferior fog fluid
the more impurities thus lead to fluid injection or blocked). All fog machines
need regular maintenance (fog machine maintenance cycle for 1 to 2
months/time). Specific maintenance method: after heating the 35% white
vinegar plus 65% distilled water and then spray 10 to 15 times.
Conclusion: As long as the fog machine with fluid injection or heater blocking
after using a period of time. It was caused by fog fluid quality or lack of
maintenance, has nothing to do with the quality of the machine. Please use the
original high quality fog fluid and timely maintain it, then it can be used for a long
time.
Pipeline has covered by dirt, insufficient
heat transfer result in water-spraying.
Dirty covered on
pipeline.
Fig 1
Fluid can not receive all heat.
Fig 2
Pipeline has covered by dirt, that
results in blocked heater.
Dirty covered on
pipeline.
Fluid can not pass.
06