background image

5.2 Tools Required

GLOVES

WASTE

CONTAINER

EYE

PROTECTION

9

5.3 Cleaning & Troubleshooting Procedure

The safety shutoff float of the Sludge Vacuum pump extends into the drum and may require occasional cleaning. Immerse the pump assembly in a mild 
cleaning or degreasing solvent. After cleaning, be sure the float moves freely. Use an air gun to remove solution and contaminants.

If the stainless steel pump becomes clogged it can be disassembled for cleaning. Use a wrench to hold the hex body firm while turning the cylindrical 
muffler assembly counterclockwise with a strapping wrench. Once the muffler assembly is removed use a pin-style. spanner wrench to unscrew the 
threaded plug. Carefully remove the shim and clean it, the O-ring and the pump body using a mild cleaning solvent. Be sure all components are dry 
before reassembling.  Note the orientation of the shim as shown in the illustration below and reinstall the threaded plug. Be careful not to over tighten the 
threaded plug as this can distort the shim and restrict airflow.

Always clean the vacuum hose and attachments after every use.

See 

APPENDIX 2:  Sludge-Vac Cleaning Instructions

If routine cleaning does not solve your performance problems, please contact  a Diversitech representative at 1-800-361-3733

Clean air is essential for proper operation of the Sludge Vacuum. A 10 micron or smaller filter separator must be used on the compressed air supply near 
the Sludge Vacuum. If the filter element becomes clogged with dirt, or a filter with a larger micron rating is us used and passes dirt into the pump, the 
airflow becomes restricted and the pump can cease to operate.

For replacement or repair filter and regulator parts, contact Diversitech at 1-800-361-3733 or [email protected]

Summary of Contents for WV-55

Page 1: ...information on this product www diversitech ca 1200 55th Avenue Montreal Quebec H8T 3J8 Tel 1 800 361 3733 Fax 1 514 631 9480 info diversitech ca READ AND SAVE THESE INSTRUCTIONS Operation Maintenanc...

Page 2: ...4 Installation 5 3 5 Preparing Unit for Operation 6 SECTION 4 OPERATION 7 4 1 To Operate Safely 7 4 2 Using The Sludge Vacuum 7 4 3 Changing The Filter Bag 8 SECTION 5 MAINTENANCE TROUBLESHOOTING 8 5...

Page 3: ...warning text to avoid the hazard 1 2 Users Responsability Improper use can be hazardous It is your responsibility to follow all applicable ANSI OSHA UL CSA National Local Fire Codes and other regulato...

Page 4: ...Connector Knob Reusable Filter Bag Model Air Consumption Water Flow Rate Sound Level Net Weight lbs Product Dimensions in SCFM SLPM GPM LPM Width in Height in Length in WV 55 Sludge Vacuum WV 55 19 5...

Page 5: ...n receiving the unit carefully examine the carton for damage during transit 2 Remove packing material 3 Avoid tipping or inverting during handling 4 The item serial number and model are listed on the...

Page 6: ...0 SLPM OIL REMOVAL FILTERS Must be rated for a supply pressure of 250 PSIG 17 2 BAR 1 72 MPa and have 0 03 micron filtration Flow should be minimum 24 SCFM 680 SLPM Remove the box of components and ac...

Page 7: ...e drum move the directional valve into the position as indicated by the label on the drum lid The Directional Valve Assembly handle extends toward the stainless steel Sludge Vac pump Turn the knob on...

Page 8: ...t it sideways The ring can then be removed from the bag holding assembly filter bag can be removed from the drum A new bag can be installed by tilting the ring and pushing it over the bag holding asse...

Page 9: ...olvent Be sure all components are dry before reassembling Note the orientation of the shim as shown in the illustration below and reinstall the threaded plug Be careful not to over tighten the threade...

Page 10: ...pied or otherwise reproduced as needed for management of maintenance records MANUFACTURER DIVERSITECH INC MODEL N SLUDGE VACUUM SERIAL N SERVICE LOCATION CONTROL N Date Description of Service Serviced...

Page 11: ...se an air gun to remove any solution and contaminants Reminder wear eye protection 2 Once the muffler assembly is removed use a pin style spanner wrench to unscrew the threaded plug 4 Clean the o ring...

Page 12: ...Spill Recovery Kit 54 Wand and Floor Tool for WV 55 S WV 0005 Replacement Reversible Drum Vac for WV 55 S WV 0006 Replacement Directional Valve Rebuild Kit for WV 55 S WV 0007 Replacement Dolly for 55...

Page 13: ...13 NOTES...

Page 14: ...14 NOTES...

Page 15: ...15 NOTES...

Page 16: ...se or use above rated capacities FREIGHT CLAIMS Shipments must be inspected upon arrival All Diversitech units are sold ex plant Therefore it is the receiver s responsibility to file any freight claim...