Quick Installation Guide - DDP3

To install the unit, create a cut-out in your countertop following the dimensions

given on the drawing and the table below.

Cooktop and

Cut-out Sizes

Cut-out Size                 565 mm         500 mm        100 mm*
                                    [22 1/4"]      [19 11/16"]         [4"]*
Cooktop Box Size          558 mm        492 mm          50 mm
                                       [22"]            [19 3/8"]           [2"]
Cooktop Rim Size          598 mm        532 mm           6 mm
                                   [23 9/16""]    [20 15/16"]        [1/4"]

Width             Depth          Thickness

*This dimension includes clearance underneath the unit of 50 mm [2"]

DDP-3 electrical characteristics are:

Operating voltage ... 220 V~ 60 Hz
Total power  ...  7600 W
Connect to   ...  220 V, 60 Hz, 2 Pole+G,

40 A supply
(3 wire #8 AWG) 

This cooktop must be installed in
accordance with pertaining local
building, trade, fire protection and
electrical codes. If local codes do
not exist, then installation must
be done in accordance with
federal codes.

The cooktop is to be connected -
hard-wired - to the electrical power
supply inside a client-supplied
junction box which should be
installed inside the cabinet below the
unit.

The unit must be properly
grounded. 

This cooktop is to be installed under
a ventilation hood or a downdraft
ventilation system.

DDP 02/06

50 [2”]

750 [30”]

Clearance

You should keep:

Above the unit to any combustible surface - 

e.g. cabinet

above the unit:   minimum clearance of 

750 mm (30”)

;

Below the unit

- between the bottom of the unit and any

horizontal partition inside your cabinet: minimum clearance
of 

50 mm (2”)

.