background image

DTK-DP4P INSTALLATION INSTRUCTIONS

 LOW VOLTAGE POWER,DATA AND VIDEO PROTECTION 

NOTE: THIS DEVICE IS NOT INTENDED FOR DIRECT EXPOSURE THE ELEMENTS. USE A NEMA 4X
OR SIMILAR ENCLOSURE FOR OUTDOOR INSTALLATIONS.

   UNPROTECTED
BNC CONNECTOR      
     VIDEO INPUT

    PROTECTED
BNC CONNECTOR
  VIDEO OUTPUT

GROUND
CONNECTOR

24V POWER,
    5V DATA
CONNECTION
      INPUTS

24V POWER,
   5V DATA
CONNECTION
    OUTPUTS

GND

OUT

VIDEO

IN

DTK-DP4P

OUT

IN

5V DATA

5V DATA

5V DATA

5V DATA

24V PWR

24V PWR

U

N

P

R

O

T

E

C

T

E

D

P

R

O

T

E

C

T

E

D

  1. CHECK THE POWER, DATA AND CABLE SIGNALS BEFORE  INSTALLATION OF THE DTK-DP4P TO VERIFY 
      NO SIGNAL DISTORTION.
  2. POWER DOWN OR DISCONNECT THE CIRCUITS THIS DEVICE WILL CONNECT TO BEFORE
      BEGINNING INSTALLATION.
  3. SECURELY MOUNT THIS UNIT BETWEEN THE FIELD WIRING AND THE EQUIPMENT TO BE PROTECTED. 
      FOR MOUNTING, USE DOUBLE-SIDED TAPE OR TWO #8 SCREWS (PROVIDED).
  4. NOTE: ALLOW THE SURGE PROTECTOR REACTION TIME BY PROVIDING 3-6 WIRE FEET OF CONDUCTOR 
      LENGTH BETWEEN THE DTK- UNIT AND THE EQUIPMENT TO BE PROTECTED.   
  5. NOTE: ALLOW FOR THE WIRE DISTANCE FROM THE SURGE PROTECTOR TO PROTECTED EQUIPMENT 
      TO BE GREATER THAN THE WIRE DISTANCE FROM THE SURGE PROTECTOR TO GROUND.
  6. FOR GROUND CONNECTION: CONNECT A MINIMUM # 14 AWG WIRE FROM THE GROUND CONNECTOR
      TO THE COMMON EARTH GROUND WITH 25 OHMS OR LESS (5 OHMS IS PREFERRED).  USE ONE COMMON 
      GROUND  PER SYSTEM TO ELIMINATE THE POSSIBILITY OF A DIFFERENCE IN GROUND POTENTIALS.
  7. FOR VIDEO PROTECTION:  CONNECT THE UNPROTECTED VIDEO CABLE INPUT FROM THE FIELD TO 
      THE BNC IN.  CONNECT ONE END OF A SECOND VIDEO CABLE FROM THE BNC OUT THEN CONNECT 
      THE OTHER END OF THIS CABLE TO THE EQUIPMENT TO BE PROTECTED.
  8. FOR DATA PROTECTION: CONNECT THE SUPPLY WIRE FROM THE FIELD TO THE UNPROTECTED 
      5V DATA TERMINALS MARKED IN .  THE SUPPLY WIRE FROM THE PROTECTED 5V DATA TERMINALS 
      MARKED OUT CONNECTS TO THE EQUIPMENT TO BE PROTECTED.
  9. FOR 24VAC POWER PROTECTION: CONNECT THE SUPPLY WIRE FOR THE 24VAC POWER SUPPLY TO
      THE UNPROTECTED 24V PWR TERMINALS MARKED IN.
      THE SUPPLY WIRE FROM THE PROTECTED TERMINALS MARKED OUT CONNECTS TO THE EQUIPMENT
      TO BE PROTECTED.
10. AFTER ALL CONNECTIONS HAVE BEEN MADE AND NO HAZARDS EXIST, RESTORE POWER.
11. CHECK THE POWER, DATA AND CABLE SIGNALS AFTER INSTALLATION OF THE DTK-DP4P TO INSURE
      PROPER INSTALL AND NO SIGNAL DISTORTION.  
12. FOR FURTHER INFORMATION OR TECHNICAL SUPPORT, PLEASE CAL 1-888-472-6100 

Diversified Technology Group, Inc.

ONE DITEK CENTER

1720 Starkey Road, Largo Fl. 33771

1-800-753-2345      www.ditekcorp.com

INSTALLATION INSTRUCTIONS FOR DTK-DP4P

CHANGED DRAWING

CHANGED INSTRUCTIONS

1
2

09-12-03

05-11-04

APP. BY:

DATE:

DATE:

DRAWN BY: 

DESCRIPTION/ECN:

DWG NO.

REV

9-12-03

TITLE:

PART NO.

REV.

RWM

INT-100007-001

191440

2

JM

JM

GND

OUT

VIDEO

IN

DTK-DP4P

OUT

IN

5V DATA

5V DATA

5V DATA

5V DATA

24V PWR

24V PWR

UNPROTECTED

24V PWR

VIDEO SIGNAL

VIDEO SIGNAL

CAMERA END

DATA SIGNAL

DATA SIGNAL

PROTECTED

LOCK         AUTO        

TIME        CAMERA   

MONITOR

PRESET 3 

PRESET 4

PRESET 1 

PRESET 2

PRESET       AUTOPAN      

WASH       WIPE       AUX     

ALARM

PAN &

TILT

ZOOM

AUTO IRIS   

OPEN     CLOSE

AUTO FOCUS 

NEAR       FAR

180

MATRIX KEYBOARD

GND

OUT

VIDEO

IN

DTK-DP4P

OUT

IN

5V DATA

5V DATA

5V DATA

5V DATA

24V PWR

24V PWR

UNPROTECTED

24V PWR

VIDEO SIGNAL

VIDEO SIGNAL

CONTROL END

DATA SIGNAL

DATA SIGNAL

MATRIX

SWITCHER

PROTECTED

OUT TO CAMERA

Reviews: