DEU
36
ENG
Commissioning
The adapters RA and RAV are pre-tensioned. For installation purposes they
can be slightly bent open with a screwdriver.
CAUTION
Danger of crushing!
There is a crushing hazard during the installation of adapters.
¾
Do not hold your fingers between the adapter halves or between adapter and valve.
1. During the installation, take care that the tabs inside the adapter (2) correspond
to the notches at the valve (1) (see fig 4 page 4).
2. Latch on the adapter completely.
3. Fix the adapter with the supplied screw and nut.
For RAV type valves, the plunger extension (3) must be attached to the
valve pin prior to installation (see fig 5 page 4).
The adapter RAVL does not need to be screwed (see fig 6 page 4).
5.4 Installation of support ring
If the radiator thermostat is loose after installation, insert the support ring (R) in
the flange (see fig 7 page 5).