28
IP1783EN - 2015-06-12
- With the door open determine the mounting position of the arm on the wing, see figure on page 8.
- Shorten the tube and if necessary the rod depending on the previously determined mounting positions
(geared motor shaft [E] and wing [C]).
WARNING: after the tube has been fit in all the way, ensure that it does not knock against the rod’s
bush or that the rod’s head does not knock against the screw that secures it to the wing (min. 5 mm).
- Mount the arm DORBD and lubricate the rod.
- Release the geared motor by pulling the cord and securing it in the release position (see
RELEASE INSTRUCTION).
- Perform a manual maneuver to ensure that the movement is devoid of obstacles or friction
and that the arm stays horizontal.
-
Re-lock the geared motor.
5
120
50
Ø5
10
25
25
10
15
25
10
50
60
50
20
60
60
Ø12
Ø18
15
40
990
590
10