Drive - 42
Cx Series Operator’s Manual
Start
Start
1. Ensure all controls are in neutral.
2. If necessary, close choke valve.
3. Insert key and activate accessories using ignition switch.
4.
If starting machine in normal conditions,
1. Start engine and run at low throttle under light load for at least three minutes before applying
heavier load.
2. Gradually open choke valve after engine warms.
If starting machine in cold weather:
1. Start engine.
2. Warm engine and hydraulic fluid by gradually increasing engine speed for up to 30 minutes.
3. After warmup, carefully operate all hydraulic controls at low throttle until controls operate as
described in controls chapter.
4. Gradually open choke valve after engine warms.
EMERGENCY SHUTDOWN:
Release all controls and stop engine.
Misuse of machine can cause death or serious injury.
Read and understand operator’s manual and all other safety instructions
before use. Know how to use all controls.
To help avoid injury:
• Allow hydraulic fluid time to warm before operating in cold weather. Cold hydraulic fluid can
lengthen ground drive stopping time.
• For starting in extreme temperatures, contact your Ditch Witch® dealer.
NOTICE:
If engine turns but does not start within 5 seconds, allow starter to cool. Wait at least one
minute and try again.