Definitions & Abbreviations

• 

Ampacity: The allowable current-carrying capacity of a 
conductor measured in amps. Ampacity is the current, in 
Amperes, that a conductor can carry continuously under 
the conditions of use without exceeding its temperature 
rating.

• 

Battery Capacity: The power a battery can deliver from 
full charge at standard temperature, and at a specified 
(usually C10) discharge rate.

• 

Circuit Breaker: Is an automatically operated electrical 
switch designed to protect an electrical circuit from 
damage caused by overload or short circuit. Its basic 
function is to detect a fault condition and interrupt 
current flow. Unlike a fuse which operates once and then 
must be replaced, a circuit breaker can be reset (either 
manually or automatically) to resume normal operation.

• 

DoD: Depth of Discharge or how deeply the battery has 
been dis-charged. Like the fuel gauge of your car, DoD is 
the measure of how much fuel you have used.

• 

I10: The constant current (I) discharge rate that can be 
maintain for 10 hours (10).

• 

MDDoD: Maximum Daily Depth of Discharge allowable

• 

MDoD: Maximum allowable Depth of Discharge

• 

OCV: Open Circuit Voltage: The voltage across the cell/
block or battery terminals with no load applied. The 
maximum possible voltage across a PV array, module, 
or cell with no load.

• 

SoC: State of Charge or how much energy is still available 
to be discharged. Like the fuel gauge of your car, SoC is 
the measure of how much gas you have left.

• 

V: The unit of measure for voltage. Voltage is the electrical 
pressure which forces the current to flow in a conductor 
such as a wire.

• 

VPC: Volts per Cel. The voltage of each individual cell, 
each cell in a block or each cell in a battery. The system 
voltage of your battery is the sum of the individual volts 
per cell.

• 

100AH C

10

: Battery has a capacity (C)of 100 amp hours(AH) 

when rated at the 10 hour (C10) rate.

• 

.3 x I10: 30% of the I10 constant current discharge rate.

Summary of Contents for Tubular Gel OPzV

Page 1: ...1 Crestwood Place Richmond BC V6V 2E9 Canada 1 778 776 3288 info discoverbattery com discoverbattery com RE Stationary Applications Tubular OPzV Gel 2V 6V and 12V Cells Blocks Tubular Gel OPzV Operating Manual ...

Page 2: ...re secure installation Use only suitable handling equipment and lifting gear Dangerous Voltage Batteries with this symbol can be recycled Do not mix with other industrial or household waste Contact your servicing Discover dealer for proper battery return and recycling Use protective glasses gloves and clothing when working on batteries Always make safe working practices a priority No Smoking Do no...

Page 3: ...Discharge Protection 6 Array to Load Ratios for Stand alone Systems 6 Low voltage Re Connect LVR for Stand alone Systems 6 3 2 Charging 6 3 2 1 Balance or Complete Charge 6 3 2 2 Equilizing charge 7 3 2 2 1 Functional Equalizing 7 3 2 2 2 Corrective Equalizing 7 3 2 3 Normal Operation Charging 7 3 2 3 1 Settings for Stand Alone Systems 7 3 2 3 2 Settings for Hybrid Systems 8 3 3 Operation at Very ...

Page 4: ...een cells or blocks The layout of the battery room or installation area must allow for easy access to the batteries The recommended minimum distance between battery rows is 1 5 times the depth of the row Racks or cabinets shall be located 100mm 4in from the wall Be sure to provide adequate space and lighting for inspection maintenance testing and cell block replacement Space should also be provide...

Page 5: ...voltage directive 73 23 EEC which confirms that the CE marking is applied to the battery The company installing the battery is responsible for the declaration and applying the CE marking For future identification apply individual cell block numbers in sequence starting from one end of the series string Also apply identification letters or numbers for the parallel strings Only connect the battery t...

Page 6: ...the supervisor nearby It lasts until certain charge criteria are fulfilled but not outside certain minimum and maximum time limits It is mainly used as Commissioning charge after installation Sec 2 8 Corrective equalizing charge Sec 3 2 2 2 Preparation charge before a capacity test Sec 6 Refresh charge during long storage period Sec 1 2 7 The battery temperature must be monitored during charge It ...

Page 7: ...l generators mainly telecom hybrid systems the charging source is always available but the boost charging time is restricted to favor a more efficient utilization of the diesel In both cases a scheduled functional equalizing charge shall be performed at regular intervals Sec 3 2 3 to protect the battery from acid stratification sulphation and loss of capacity Functional Equalizing frequency is adj...

Page 8: ...and alone systems with oversized PV array and very low MDDoD 5 e g remote telecom transmitters In these circumstances use the following settings The temperatures are average over one month Stand Alone Systems Hybrid Systems When only the PV is engaged use settings shown in Constant Voltage One Step When only the diesel is engaged continuously use Constant Voltage Two Step and reduce the settings b...

Page 9: ...phs BatteryVoltage in relation to DoD as guidance for the initial LVD settings first try settings 25 C 77 F reference temperature 25ºC reference temperature DoD100 DoD90 DoD80 DoD70 DoD60 DoD50 DoD40 DoD30 DoD20 Minimum for Standby use MINIMUM FOR SOLAR USE 1 75 1 80 1 85 1 90 1 95 2 00 2 05 2 10 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 Battery Voltage Vpc Extracted Amperhours per 100A...

Page 10: ...ischarge or how deeply the battery has been dis charged Like the fuel gauge of your car DoD is the measure of how much fuel you have used I10 The constant current I discharge rate that can be maintain for 10 hours 10 MDDoD Maximum Daily Depth of Discharge allowable MDoD Maximum allowable Depth of Discharge OCV Open Circuit Voltage The voltage across the cell block or battery terminals with no load...

Reviews: