background image

Danish Interpretation Systems 

 

User Manual 

 

Manual 01 18 04450 

 

Important 

Compliancy 

The equipment has been tested and found to comply 
with the limits of the following standards for digital 
devices: 

 

EN55103-1  (Emission) 

 

EN55103-2 (Immunity 

 

EN60065 safety 

 

UL6500 safety 

 

FCC rules part 15, class A (Emission) 

This device complies with part 15 of the FCC rules. 
Operation is subject to the following conditions: (1) 
This  device  may  not  cause  harmful  interference, 
and  (2)  this  device  must  accept  any  interference 
received,  including  interference  that  may  cause 
undesired operation

.

 

These  limits  are  designed  to  provide  reasonable 
protection  against  harmful  interference  when  the 
equipment is operated in residential, commercial or 
light  industrial  environments.  The  equipment 
generates,  uses,  and  can  radiate  radio  frequency 
energy  and  if  not  installed  and  used  in  accordance 
with  the  user  manual  it  may  cause  harmful 
interference to radio communications. 

You 

are 

cautioned 

that 

any 

changes 

or 

modifications not expressly approved in this manual 
could void your authority to operate this equipment. 

Safety 

Check that the voltage of your local power supply is 
within  the  operating  voltage  of  the  unit (100-240V 
AC).  If  a  voltage  conversion  is  required,  consult 
your DIS dealer or qualified personnel. 

Should  any  liquid  or  solid  object  fall  into  the 
cabinet,  unplug  the  unit  and  have  it  checked  by 
qualified personnel before operating it further. 

Set  the  Power  switch  to  OFF  if  it  is  not  used  for 
several days.  

The equipment must be connected to earth

 

Installation precautions 

Allow  adequate  air  circulation  to  prevent  internal 
heat  built-up.  Do  not  place  the  unit  on  a  surface 
(rugs, blankets, etc.) that may block the ventilation 
holes. 

Do  not  install  the  unit  in  a  location  near  heat 
sources such as radiators or air ducts, or in a place 
exposed  to  direct  sunlight,  excessive  dust  or 
humidity, mechanical vibration or shock. 

To  avoid  moisture  condensations  do  not  install  the 
unit where the temperature may rise rapidly. 

When installing the unit inside a 19” rack, observe 
that  the  rack  is  properly  ventilated.  The  maximum 
allowed temperature inside the rack is 40 

°

C. 

Cleaning & Repacking 

To  keep  the  cabinet  in  its  original  condition, 
periodically  clean  it  with  a  soft  cloth.  Stubborn 
stains  may  be  removed  with  a  cloth  lightly 
dampened with a mild detergent solution. Never use 
organic  solvents  such  as  thinners  or  abrasive 
cleaners since these will damage the cabinet. 

Save  the  original  shipping  cardboard  box  and 
packing  material;  they  will  become  handy  if  you 
ever have to ship the unit. For maximum protection, 
re-pack  the  unit  as  originally  packed  from  the 
factory. 

Warranty 

The  unit  is  minimum  covered  by  12  months 
warranty  against  defects  in  materials  or  work-
manship.

Summary of Contents for PS 6000

Page 1: ...DCS 6000 User Manual Danish Interpretation Systems DIS Digital Conference System PS 6000 Power Supply ...

Page 2: ...rpretation Systems User Manual Copyright 2007 DIS PS6000 REV B DOC 21 05 2007 No part of this publication may be reproduced or utilised in any form or by any means without permission in writing from the publisher ...

Page 3: ... 6 Conference equipment and channel selectors 6 Operating instructions 7 PS 6000 Power Supply 7 General description 7 Features 7 Connectors 7 System design 7 Use of PS 6000 8 System Setup 9 General guidelines 9 Max number of units to be connected 10 CM DM 60x0P Chairman Delegate Units 10 CM DM 60x0P Chairman Delegate Units JB 6002 Junction Box 10 CM DM 6060F 6510F Chairman Delegate Units 11 CM DM ...

Page 4: ... personnel Should any liquid or solid object fall into the cabinet unplug the unit and have it checked by qualified personnel before operating it further Set the Power switch to OFF if it is not used for several days The equipment must be connected to earth Installation precautions Allow adequate air circulation to prevent internal heat built up Do not place the unit on a surface rugs blankets etc...

Page 5: ...he system Using screened CAT5 or CAT5e cabling FTP or STP ensuring a very cost effective installation and easy set up of portable systems Firmware in Delegate units Interpreter Units Central Units etc upgradeable through serial PC connection RS232 or RS422 Can be operated with or without a PC Added functionality and comprehensive features provided by SW 6000 software package running on PC RS232 RS...

Page 6: ... portable DM 6060P Conference Unit portable with one built in channel selector CM DM 6070P Conference Unit portable with two built in channel selectors CM DM 6090P Conference Unit portable with two built in channel selectors and XLR microphone connector CM DM 6060F Conference Unit flush mounted with one built in channel selectors CM DM 6510F Conference Unit flush mounted with Chip card and 3 votin...

Page 7: ...res the following connectors Power connector Connection for main power Loop through connectors RJ45 connector 2 pieces DCS LAN connectors used for connection to the CU 6005 6010 and for connection to other units with DCS LAN connectors such as more PS 6000 Power LED Those green LED light up when Power is available on the connector next to the LED System design There are no settings to be done on t...

Page 8: ... 6000 chain where extra power is needed The PS 6000 is used when extra power is needed typically where long feeding cables are needed A typical application is to place a PS 6000 in the first Interpreter Booth to compensate for a long feeding cable The following schematic shows various ways in how to use the PS 6000 Power Supply ...

Page 9: ...m the PS 6000 to the units connected If the feeding cables are short and the cables between the units are short more units can be connected than if the feeding cable is long and or the cables are long between the units Please consult the next section Max Number of units to be connected If the last unit in one chain is a CS 6032 Channel Selector this unit has to be terminated with an external termi...

Page 10: ...umber of CM DM 60x0 pr output 10 m 1 m 51 m 42 30 m 1 m 67 m 38 50 m 1 m 83 m 34 100 m 1 m 123 m 24 150 m 1 m 165 m 16 10 m 2 m 88 m 40 30 m 2 m 98 m 35 50 m 2 m 108 m 30 100 m 2 m 142 m 22 150 m 2 m 180 m 16 CM DM 60x0P Chairman Delegate Units JB 6002 Junction Box This configuration shows two CM DM 60x0 Delegate Chairman Units connected to one JB 6002 Junction Box with 3m cables between each JB 6...

Page 11: ... AWG24 Length of inter connecting Cable Type CAT5 AWG24 Total cable length Max number of CM DM 60x0 pr output 10 m 1 m 39 m 30 30 m 1 m 56 m 27 50 m 1 m 73 m 24 100 m 1 m 115 m 16 150 m 1 m 160 m 11 10 m 2 m 64 m 28 30 m 2 m 78 m 25 50 m 2 m 94 m 23 100 m 2 m 130 m 16 150 m 2 m 170 m 11 CM DM 6560F Chairman Delegate Units Length of Feeding Cable Type CAT5 AWG24 Length of inter connecting Cable Typ...

Page 12: ...are the number of units which could have been connected CU EX but where the total number of units has been lowered due to the restriction of the maximum length of cable 200 m IS 6132P Interpreter Units This table shows the maximum number of IS 6132P Interpreter Sets which can be connected The numbers are with no audio in loudspeaker no loudspeaker connected to each unit If loudspeakers are used th...

Page 13: ... 0 150 m 5 m 5 4 4 CS 6032F Channel Selector w back light on Length of Feeding Cable Type CAT5 AWG24 Length of Inter connecting cable Type CAT5 AWG24 Total cable length Max number of CS 6032 pr output 30 m 1 m 139 m 110 50 m 1 m 144 m 95 100 m 1 m 184 m 85 150 m 1 m 200 m 51 67 10 m 2 m 200 m 96 30 m 2 m 200 m 86 90 50 m 2 m 200 m 76 85 100 m 2 m 200 m 51 70 150 m 2 m 200 m 26 60 Numbers in are th...

Page 14: ...les can normally only be terminated in sockets female and not in cable plugs CAT6 can thus only be used for longer cable draws terminating in wall outlets or patch panels Accessories not supplied Cat 5e Connection Cables AWG24 EC 6000 5 Connection Cable 0 5 m 10 03 12500 EC 6000 01 Connection Cable 1 m 10 03 13101 EC 6000 02 Connection Cable 2 m 10 03 13201 EC 6000 05 Connection Cable 5 m 10 03 13...

Reviews: