Danish Interpretation Systems
User Manual
Manual 01 18 04450
10
Max. number of units to be connected
The following tables show the maximum number of
units, which can be connected to the two outputs
(A1 or A2) on a CU 6005 Central Unit in total or to
each of the four outputs (A1, A2, B1 or B2) on a
CU 6010 Central Unit or to each output on an EX
6010 Extension Unit or to the output of a PS 6000
Power Supply.
CM/DM 60x0P Chairman/Delegate Units
Length of Feeding Cable
Type CAT5 AWG24
Length of inter connecting
Cable, Type CAT5 AWG24
Total cable length
Max. number of CM/DM
60x0 pr output
10 m
1 m
51 m
42
30 m
1 m
67 m
38
50 m
1 m
83 m
34
100 m
1 m
123 m
24
150 m
1 m
165 m
16
10 m
2 m
88 m
40
30 m
2 m
98 m
35
50 m
2 m
108 m
30
100 m
2 m
142 m
22
150 m
2 m
180 m
16
CM/DM 60x0P Chairman/Delegate Units & JB 6002 Junction Box
This configuration shows two CM/DM 60x0
Delegate/Chairman Units connected to one JB 6002
Junction Box with 3m cables between each JB
6002. Maximum 5 m cable from JB 6002 to
CM/DM 60x0 and max. one CM/DM 60x0 on each
output of JB 6002.
Length of Feeding Cable,
Type CAT5 AWG24
Length of Cable between each
JB 6002, Type CAT5 AWG24
Total cable
length
Number of
JB 6002
Max. number of
DM 60x0
10 m
3 m
61 m
18
36
30 m
3 m
75 m
16
32
50 m
3 m
89 m
14
28
100 m
3 m
127 m
10
20
150 m
3 m
168 m
7
14