User Manual - QG65N2 SAE J1939 Inclinometer (Type JB) V1.1
9.4.
Save changes to the sensor
Use index 1010
h
sub-index 01
h
Byte 0-1
Index = 1010
h
Byte 2
CMD = 02
h
, write to the sensor.
Byte 3
Sub index = 01
h
Byte 4-7
Write 65766173
h
(save)
9.5.
Restore factory default
Use index 1011
h
sub-index 01
h
Byte 0-1
Index = 1011
h
Byte 2
CMD = 02
h
, write to the sensor.
Byte 3
Sub index = 01
h
Byte 4-7
Write 64616F6C
h
(load)