background image

1

H.265/264 1080P HDMI Encoder

Operating Instruction

Best.nr: 20110042

Summary of Contents for H.265/264

Page 1: ...1 H 265 264 1080P HDMI Encoder Operating Instruction Best nr 20110042 ...

Page 2: ...ting or adjusting this product Please keep this manual for future reference SURGE PROTECTION DEVICE RECOMMENDED This product contains sensitive electrical components that may be damaged by electrical spikes surges electric shock lightning strikes etc Use of surge protection systems is highly recommended in order to protect and extend the life of your equipment ...

Page 3: ...oder Mode 6 1 Features 6 2 Wiring Diagram 6 3 Connecting 7 4 Device Setting Description 8 4 1 Change IP address from PC 8 4 2 Log in by browser 8 4 3 Status 9 4 4 Encoder 9 4 5 Main stream 9 4 6 Sub stream 10 4 7 Video Settings 10 4 8 Audio setting 10 4 9 OSD Setting 11 4 10 System Setting 12 MAINTENANCE 14 PRODUCT SERVICE 14 WARRANTY 14 ...

Page 4: ...bit HDCP Compliant HDCP1 4 Audio Format Supported Input LPCM2 0 Sample rate 44 1KHz and 48KHz Audio Encode AACLC AAC AAC Audio bit rate AACLC 48 320 AAC 32 128 AAC 16 64 RS 232 serial port 3PIN terminal block connectors Ethernet port IP control RJ45 female Default IP 192 168 1 168 Dimensions WxHxD 124 90 21mm Net Weight 300g Power consumption DC12V1A 4W Max 3 Input Resolution List Fresh Rate I P R...

Page 5: ...5 8BIT P 1080P 24Hz 8BIT P 720P P 1080P 25Hz 8BIT P 720P P 1080P 3 1 VESA Resolution List Resolution Support 800 600 1024 768 1280 768 1280 1024 1600 1200 1680 1050 1920 1080 1280 720 1360 768 ...

Page 6: ...pports AAC AAC AAC Maximum support 2 channel video stream decoding support 1 channel only audio stream decoding Support HDCP1 4 HDMI IN resolution supports the maximum 1080P60Hz 4 4 4 8 bit with one loop out Support CBR VBR two coding modes maximum code rate up to 40Mbps Main code stream is 40M Sub code stream is 8M Support analog audio extraction and analog audio embedded DC 12V 1A the maximum po...

Page 7: ...onnecting DC12 1A Power input port RS232 Port Ethernet port Audio Embedded port Analog Audio Extraction port HDMI Input Indicator HDMI Input port HDMI Output Indicator HDMI Output port Reset button Long press 3s to reset the unit ...

Page 8: ...r and the device were set in the same network segment 1 Open the network control center and set the computer s IP address 2 Choose to use Static IP with the IP address set to 196 168 1 x x ranges from 0 to 254 but cannot be consistent with the device s IP address 192 168 1 168 3 Subnet mask set to 255 255 255 0 4 2 Log in by browser Default IP address for log in 192 168 1 168 Type in user name and...

Page 9: ... 1 Channel address can support RTSP HLS RTMP S UDP RTP protocol 2 The maximum support 1920 1080 60fps resolution decoding Main stream default auto decoding 3 Bit rate kbps maximum support 2 40960 FPS maximum support 1 90 key frame interval maximum support 1 300 bit rate statistical interval seconds 1 60 bitstream control support CBR and VBR ...

Page 10: ...el including baseline Profile Main Profile and High Profile 4 7 Video Settings 1 Video input setting included Rotation Mirroring Flipping etc 2 Rotation include 90 180 270 3 Video source signal clipping can be used to clip images within the resolution range Note that it will not take effect until it is started and it is disabled by default Note The parameters for starting point cut and cutting wid...

Page 11: ...z bit rate 128 default Support Enable RTSP Audio stream transfer or modify audio stream transfer address Support to set sampling rate when HDMI audio input is enabled Audio Output Audio output support to set HDMI loop audio output and analog audio output 4 9 OSD Setting Support setting 4 OSDs supporting setting Format text date style font size color etc After setting can be viewed in the main code...

Page 12: ...5 0 Mac address factory fixed support modification restore after reset Port Settings RTSP anonymous Access Enable means that no account and password need to be input when receiving video stream otherwise account and password needed The modified IP address cannot be the same as the IP address of all connected devices in the network Password Setting Default account admin Password admin Serial port s...

Page 13: ...13 Operating Instruction Upload firmware and configuration and backup Time and date setting Factory reset Reboot Schedule Restart Language Setting ...

Page 14: ...the date of original purchase Limited Warranty period at its option either a repair your product with new or refurbished parts or b replace it with a new of a refurbished product The decision to repair or replace will be made by the warrantor During the Labor Limited Warranty period there will be no charge for labor During the Parts warranty period there will be no charge for parts You must mail i...

Page 15: ...ES RESULTING FROM THE USE OF THIS PRODUCT OR ARISING OUT OF ANY BREACH OF THIS WARRNTY As examples this excludes damages for lost time cost of having someone remove or re install an installed unit if applicable travel to and from the service loss of or damage to media or images data or other recorded content The items listed are not exclusive but are for illustration only 3 PARTS AND SERVICE WHICH...