28
Operating Instruction
Operation of TCP/UDP port number change
①
Select “Config” in the main menu and press “ENTER”
②
Press “UP” or “DOWN” to select “ network ”
③
Click “ENTER” to enter the next sub-menu
④
Press “UP” or “DOWN” to select baud rate “Port” to enter the next sub-menu
⑤
Select “UDP” or “TCP”
⑥
Press “UP” or “DOWN” to select “1~65534” to complete the operation.
2) RS-232
Data, Stop, and Parity parameters cannot be changed by default. Only baud rate can be change.
Other parameters can be changed only when the read/write permission is enabled by instruction,
which is not enabled by default
Operation:
①
Select “Config” in the main menu and press “ENTER”
②
Press “UP” or “DOWN” to select “ RS232 ”
③
Click “ENTER” to enter the next sub-menu
④
Press “UP” or “DOWN” to select baud rate “Baud” to enter the next sub-menu
⑤
Select “4800~115200” and press”ENTER” to complete the operation
3) LCD
Bright can adjust the brightness of the LCD screen, and Timer can set the backlight time. The default
backlight level is 8 and the time is 30 seconds.