LED diagnostics and troubleshooting
This section provides LED diagnostics and troubleshooting information to guide you through the various stages of
your installation.
For more details on "Remote start shutdown/startup diagnostics", refer to the Analog Installation guide, which
can be found on www.directechs.com.
Module programming
LED
Description
Troubleshooting
Comment
Solid red
Waiting to begin
the programming
sequence.
Make sure that all the connections are
correct
(see wiring diagram).
Normal operation.
Flashes green
Bypass and CAN
detected.
Both CAN and Bypass connections are
good. Turn ignition OFF and back ON
again to complete programming.
Normal operation.
Flashes orange
Bypass done,
connect to XpressVip.
com.
Normal operation
Normal operation.
Solid green
x 3 seconds
Module was
successfully
programmed.
Normal operation
Normal operation.
Solid orange
x 3 seconds
Module was
successfully
programmed without
transponder bypass.
Normal operation - Module will operate the
convenience only (no bypass).
Normal operation.
Module programming - Error codes
LED
Description
Troubleshooting
Comment
Flashes red x 2
CAN2 not detected.
Check the Tan - Tan/Black wire connections.
Wake up the data bus by turning the ignition
on and try again. HS and MS CAN wires
may be swapped.
Some installation types do not need this
connection. Skip by pressing the programming
button 5 times.
Flashes red x 3
Bypass data not
detected.
Check the bypass line connection. Make
sure that Immobilizer Clock and Immobilizer
Data are not inverted AND that there
is continuity between both sides of the
Immobilizer Data cut.
Start vehicle using the key to confirm the OEM
equipment is still operational.
Flashes red x 5
Immobilizer Clock
connection not
detected.
Yellow/Black wire did not detect the
expected signal. Make sure that the battery
is removed from key fob and that the key is
inserted into the key port.
Refer to "Installation" on page 8 to check the
connections.
Flashes red x 6
Immobilizer Data
connection not
detected.
Orange/Black wire did not detect the
expected signal. Make sure that there
is continuity between both sides of the
Immobilizer Data cut.
Refer to "Installation" on page 8 to check the
connections.