background image

3

© 2009 Directed Electronics

Using your system

Manual (active) arming

The factory default is active arming. You can activate or arm the sys-

tem by locking the doors with your factory keyless entry transmitter.

When the system arms, you will hear a short siren chirp and see the

parking lights flash once. 

While the system is armed the status LED flashes about twice a sec-

ond, to show that the system is actively protecting your vehicle. If you

hear a second short siren chirp after arming, and the status LED is

flashing in groups, then go to Diagnostics section (page 9). This extra

short siren chirp is called Bypass Notification.

Automatic (passive) arming

The system also can be programmed to arm itself automatically

(called passive arming). If the system is programmed for passive

arming, it will automatically arm 30 seconds after the ignition is turned

off and the system  sees  you leave the vehicle by opening and clos-

ing a door. Whenever the system is in its 30-second passive-arming

countdown, the status LED will flash twice as fast as it does when the

system is armed. When the system arms, you will hear a short siren

chirp and the parking lights will flash once. The doors lock (if con-

nected and programmed for passive locking).

N

Noottee:: If the ignition is turned on within 60 seconds of
arming the system, the system will automatically disarm.

N

Noottee:: The system can be programmed to sound horn honks or
siren chirps. The horn is optional and may require additional
labor.

Summary of Contents for AVITAL 3001L

Page 1: ...Av i tal 3001L Owner s Guide...

Page 2: ...2 2009 Directed Electronics...

Page 3: ...se FOR A CHARGE OF 45 00 SO LONG AS THE AFOREMENTIONED CONDITIONS HAVE BEEN MET The unit must be returned to Directed postage pre paid along with a legible copy of the receipt including the informatio...

Page 4: ...and you may also have other rights which vary from state to state This warranty is void if the unit has not been purchased from Directed or an authorized Directed dealer or if the unit has been damag...

Page 5: ...ode 7 Nuisance prevention circuitry 8 Diagnostics 9 Arming diagnostics 9 Disarming diagnostics 9 Table of zones 10 Rapid resume logic 10 Programming options 11 Programming settings 11 Glossary of term...

Page 6: ...m Due to the complexity of this system it must be installed by an authorized deal er only I n s tallation of this product by anyone other than an autho rized dealer voids the warranty All dealers are...

Page 7: ...system also can be programmed to arm itself automatically c a l l e d passive arming If the system is programmed for passive arming it will automatically arm 30 seconds aft e rt h ei g n i t i o ni s...

Page 8: ...ing continuously and flashing pa r k i n g l i g h ts If a door is opened the system immediately sta r ts short c h i r ps of the siren and flashes the pa r k i n g l i g h ts Three seconds later the...

Page 9: ...d it be lost damaged or disabled To do this you must have the vehicle s ignition key and know where the Va l e t s w i t c h i s l o c a t e d Tu r n t h e i g n i t i o n t o t h e r u n p o s i t i...

Page 10: ...steady if you have entered Valet Mode To e x i tValet Mode repeat the steps above The LED turns off when exit ing Valet Mode Remote valet Remote Valet is a convenient feature that makes bypassing the...

Page 11: ...Options If enabled just press the lock button on your factory keyless trans mitter twice within three seconds to enter Panic Mode The siren sounds and the pa r k i n g l i g h ts flash for 30 seconds...

Page 12: ...any other sensors or switches sharing the same zone for 60 minutes If the bypassed sensor tries to trigger the system while it is being bypassed the 60 minute bypa s s p e r i o d w i l l s ta r t o v...

Page 13: ...e seconds later it will monitor that input normally F o r e x a m p l e i f y o u r c a r h a s i n t e r i o r l i g h t e x i t delay and you arm the system before the interior light goes out you ma...

Page 14: ...rigger 4 Optional sensor 5 Ignition trigger The LED will not report if the Wa r n Away response is triggered Rapid resume logic This system will store i ts c u r r e n t s tate to non volatile memory...

Page 15: ...ng 30 seconds after closing the last door 2 Arming disarming confirmation chirps on or off 3 Door Trigger Error Chirp on or off 4 Ignition controlled domelight on or off 5 Panic Auxiliary Channel This...

Page 16: ...y a full trigger response when the door is opened In the instant mode the system will trigger the full trigger response 8 Sensor shunt zones 2 and 4 or All zones 9 Siren duration 30 seconds or 60 seco...

Page 17: ...Input Any physical connection to the security system An input can be provided through a sensor pinswitch or by existing systems in the vehicle such as ignition or courtesy lights LED The LED indicates...

Page 18: ...14...

Page 19: ...15 2009 Directed Electronics Notes...

Page 20: ...16 2009 Directed Electronics Notes...

Page 21: ...es within 10 seconds Default is 1 Possible set tings are from 1 to 5 The system should now disarm If it does not you may have waited too long Turn the ignition off and on and try again To enter or exi...

Page 22: ...or hood trunk pin switches 2 Instant trigger a heavier impact detected by the shock sensor 3 Door switch trigger 4 Optional sensor 5 Ignition trigger The LED will not report if the Wa r n Away respons...

Page 23: ...19...

Page 24: ...in the field of advanced electronic technology DIRECTED is ISO 9001 registered Quality Directed Electronics products are sold and serviced throughout North America and around the world C a l l 800 274...

Reviews: