Direct Healthcare Services Dyna-Form Mercury Safety 7 User Manual Download Page 1

User Manual

D I R E C T H E A L T H C A R E S E R V I C E S . C O . U K

Mercury Safety 7

Summary of Contents for Dyna-Form Mercury Safety 7

Page 1: ...User Manual D I R E C T H E A L T H C A R E S E R V I C E S C O U K Mercury Safety 7 ...

Page 2: ...aning care 4 3 1 Light Soiling 4 3 2 Heavy Soiling 5 3 3 Drying 5 3 4 Inspection 5 4 Maintenance 5 4 1 Audit 5 5 After Use 5 5 1 Storage 5 5 2 Transport 5 5 3 Re Use 5 5 4 Disposal 6 6 Quality Testing 6 6 1 Service Life 6 6 2 Product Warranty Periods 6 6 3 Fire Testing 6 6 4 Quality Standards 6 7 Technical Data 6 This manual must be given to the user of the product Before using the product read th...

Page 3: ...n YourDyna FormTM MercurySafety7Mattressutilisesahighspecificationpolyurethanemultistretch vapour permeable coverwhichis designedtoreducebuild upofheatthatisassociatedwithPVCtypemattresscoverswhilststillremainingwaterproof Underthecover thismattressblendsthefinestqualitycombustionmodifiedetherfoam CME togetherwithaseriesofaircellsthatensuresthisproduct providesnotonlythebestpressurere distribution...

Page 4: ...onal increase of body temperature which may cause skin maceration is not advisable Please seek clinical advice should you wish to use any covering other than the cotton or linen type bed sheet Take care when using mechanical items such as bridging boards PAT slides or other patient transfer aids that damage does not occur to the mattress cover due to sharp or damaged edges WARNING The maximum user...

Page 5: ... be withdrawn from service The Company suggests that bed frame should also be cleaned in between each change of patient 4 Maintenance 4 1 Audit CAUTION It is recommended that a minimum of a 6 monthly or annual audit of all mattresses within a ward department should be adhered to In the community setting an audit should also be considered between each change of patient Please refer to documents Foa...

Page 6: ...ion of the mattress No responsibility will be accepted for damage caused by misuse or non observance of the instructions set out in this user guide Full warranty terms and conditions are available on request 6 3 Fire testing Direct Healthcare products are independently fire tested Covers adhere to BS 7175 crib 5 Cushions adhere to BS 7176 crib 5 Mattresses adhere to BS 7177 crib 5 adherence to cri...

Page 7: ...unction with appropriate clinical judgement and nursing procedures All products manufactured to standards With over 28 years experience in the provision of clinically proven value for money solutions you can be sure that our combination of innovative technologies designed in partnership with leading clinical healthcare establishments meet the needs of most patient groups including our increasingly...