background image

1

1

CONTENTS

Use the remote controller within a distance of 8 
meters from the appliance, pointing it towards the 
receiver. Reception is confirmed by a beep.

Location of  the remote controller.

8m

CAUTIONS

The air conditioner will not operate if curtains, doors or other materials 
block the signals from the remote controller to the indoor unit.
Prevent any liquid from falling into the remote controller. Do not expose 
the remote controller to direct sunlight or heat.
If the infrared signal receiver on the indoor unit is exposed to direct 
sunlight, the air conditioner may not function properly. Use curtains to 
prevent the sunlight from falling on the receiver.
If other electrical appliances react to the remote controller. either move 
these appliances or consult your local dealer.

The remote controller is powed by two dry batteries(R03/LR03X2) housed in the 
rear part and protected by a cover.
(1) Remove the cover by pressing and sliding off.
(2) Remove the old batteries and insert the new batteries,placing the(+) and (-) 
      ends correctly.
(3) Reattach the cover by sliding it back into position.

NOTE: 

When the batteries are removed, the remote controller erases all progra-

mming.  After inserting new batteries, the remote controller must be reprogrammed.
  

Replacing batteries

Handling the remote controller

2

2

Keep the remote controller  where its signals can  
reach the receiver of the unit. When you select the 
timer operation, the remote controller automatically 
transmits a signal to the indoor unit at the specified
time. If you keep  the  remote controller in a position   
that hinders proper signal transmission, a time lag of 
up to 15 minutes may occur.

CAUTIONS

Do not mix old and new batteries or batteries of different types.
Do not leave the batteries in the remote controller if they are not 
going to be used for 2 or 3 months.
Do not dispose batteries as unsorted municipal waste. Collection of such 
waste separately for special treatment is necessary.

2

3

5

7

8

8

8

9

9

10

13

Handling the remote controller ......................................................

Remote controller Specifications...................................................

Function buttons .................. .........................................................

Indicators on LCD ..........................................................................

How to use the buttons ................................................................. 

Auto operation.................................................................................

Cooling/Heating/Fan operation......................................................

Dehumidifying operation ...............................................................

Adjusting air flow direction............................................................

Timer operation...............................................................................

SLEEP/FRESH function..................................................................

Summary of Contents for RG52A2/BGCEF

Page 1: ... you very much for purchasing our air conditioner Please read this owner s manual carefully before using your air conditioner The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details ...

Page 2: ...d ends correctly 3 Reattach the cover by sliding it back into position NOTE When the batteries are removed the remote controller erases all progra mming After inserting new batteries the remote controller must be reprogrammed Replacing batteries Handling the remote controller 2 2 Keep the remote controller where its signals can reach the receiver of the unit When you select the timer operation the...

Page 3: ...e fan speed in four steps AUTO LOW MED HIGH FAN Button Active Disable Self Clean function SLEEP Button FRESH Button For RG52A3 BG C EFmodels only NOTE While the unit is running under SLEEP mode it would be cancelled if MODE FAN SPEED or ON OFF button is pressed Active Disable sleep function It can maintain the most comfortable temperature and save energy This function is available on COOL HEAT orA...

Page 4: ... this button to increase the indoor o o temperature setting in 1 C increments to 30 C FOLLOW ME Button Push this button to initiate the Follow Me feature the remote display is actual tempera ture at its location The remote control will send this signal to the air conditioner every 3 minutes interval until press the Follow Me button again The air conditioner will cancel the Follow Me feature automa...

Page 5: ...ailable 1 Press the MODE button to select COOL HEAT cooling heating models only or FAN mode 2 Press the UP DOWN buttons to set the desired temperature 3 Press the FAN button to select the fan speed in four steps Auto Low Med or High 4 Press the ON OFF button to start the air conditioner The temperature can O O O be set within a range of 17 C 30 C in 1 C increments In the FAN mode the setting tempe...

Page 6: ... the remote controller transmits the signal to the air conditioner Then after approximately another 2 seconds the signal h will disappear and the set temperature will re appear on the LCD display window To set the Auto on time To set the Auto off time 1 Press the TIMER OFF button The remote controller shows TIMER OFF the last Auto off setting time and the signal H will be shown on the LCD display ...

Page 7: ...ater Auto off Operation The TIMER OFF feature is useful when you want the unit to turn off automatically after you go to bed The air conditioner will stop automatically at the set time To stop the air conditioner in 10 hours 1 Press the TIMER OFF button the last setting of stopping operation time and the signal H will show on the display area 2 Press the TIMER OFF button to display 10H on the TIME...

Page 8: ...mperature again The TIMER ON OFF indicator remains on and this function is activated Off Stop Start 2 hours later after setting 5 hours later after setting Set NOTE The timer setting TIMER ON or TIMER OFF that in sequence occurs directly after the set time will be activated first SLEEP function The sleep function enables the unit to automa tically increase cooling or decrease heating O 1 C per hou...

Reviews: