Dual Output Off-Line Non-isolated Flyback Power Solution
AP3917B 12V/20mA+3.8V20mA EV3 Board User
’s Guide
AP3917B EV3 Page 15 of 17 06-21-2019
Rev 1.0 www.diodes.com
Fig. 5-27, IC 34.5
℃
, 12V flyback diode 31.5
℃
, RCD diode
@full load, 265V/50Hz, ambient temperature 26.3
℃
.
Fig. 5-28, Transformer 33.5
℃
, 3.8V flyback diode 31.8
load, 264V/50Hz, ambient temperature 25.4
℃
.
5.5 System EMI Scan
The power supply passed EN55022 Class B (for 230V input) and FCC part 15 (for 110V input) EMI requirement with more than
6dB margin.
5.5.1 Conduction EMI test of 230V@full load
The test result can pass EN55022 Class B limitation with more than 6dB margin.
Fig. 5-29, L line conduction waveform@230V, full load.
Fig. 5-30, L line conduction data@230V, full load.