2 Installation
SBC300 Session Border Controller
Copyright©2011-2018 Dinstar
9
Wire sequence of 568B: white & orange, orange, white & green, blue, white & blue, green, white & brown, brown.
Step3.
Put the wires into the PINs of a RJ45 joint according to the abovementioned wire sequence of EIA/TIA
568B, and then use a wire crimper to crimp the RJ45 joint.
Step4.
On the other end of the network cable, sequence the wires of the cable according to EIA/TIA 568A
Standard (as shown in the following figure);
Wire sequence of 568A: white & green, green, white & orange, blue, white & blue, orange, white & brown, brown.
Step5.
Put the wires into the PINs of a RJ45 joint according to the abovementioned wire sequence of EIA/TIA
568A, and then use a wire crimper to crimp the RJ45 joint.
Step6.
Test the usability of the network cable.
Troubleshooting about Network Connection
When the SBC300 device has been connected to gigabit Ethernet, but the SPEED and LINK indicators on the front
panel of the device are still dull, it can be concluded that network connection fails.
You can try to find the reasons for network connection failure according to the following steps.